AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE

被引:218
|
作者
GORTON, L [1 ]
JONSSONPETTERSSON, G [1 ]
CSOREGI, E [1 ]
JOHANSSON, K [1 ]
DOMINGUEZ, E [1 ]
MARKOVARGA, G [1 ]
机构
[1] UNIV ALCALA DE HENARES, DEPT NUTR & FOOD ANAL, E-28871 ALCALA DE HENARES, SPAIN
关键词
BIOSENSOR; DIRECT ELECTRON TRANSFER; AMPEROMETRY; ELECTRODE; IMMOBILIZED ENZYME;
D O I
10.1039/an9921701235
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An apparent direct electron transfer between various electrode materials and peroxidases immobilized on the surface of the electrode has been reported in the last few years. An electrocatalytic reduction of hydrogen peroxide stars at about +600 mV versus a saturated calomel (reference) electrode (SCE) at neutral pH. The efficiency of the electrocatalytic current increases as the applied potential is made more negative and starts to level off at about -200 mV versus SCE. Amperometric biosensors for hydrogen peroxide can be constructed with these types of peroxidase modified electrodes. By co-immobilizing a hydrogen peroxide-producing oxidase with the peroxidase, amperometric biosensors can be made that respond to the substrate of the oxidase within a potential range essentially free of interfering electrochemical reactions. Examples of glucose alcohol and amino acid sensors are shown.
引用
收藏
页码:1235 / 1241
页数:7
相关论文
共 50 条
  • [1] Electron-transfer mechanisms in amperometric biosensors
    K. Habermüller
    M. Mosbach
    W. Schuhmann
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 560 - 568
  • [2] Electron-transfer mechanisms in amperometric biosensors
    Habermüller, L
    Mosbach, M
    Schuhmann, W
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (6-7): : 560 - 568
  • [3] DIRECT ELECTRON-TRANSFER BETWEEN IMMOBILIZED CYTOCHROME-C AND GOLD ELECTRODES
    COOPER, JM
    THOMPSON, G
    MCNEIL, CJ
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS SCIENCE AND TECHNOLOGY SECTION A-MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1993, 234 : 409 - 414
  • [4] Amperometric Biosensors Based on Direct Electron Transfer Enzymes
    Schachinger, Franziska
    Chang, Hucheng
    Scheiblbrandner, Stefan
    Ludwig, Roland
    MOLECULES, 2021, 26 (15):
  • [5] Minizymes. A new strategy for the development of reagentless amperometric biosensors based on direct electron-transfer processes
    Lotzbeyer, T
    Schuhmann, W
    Schmidt, HL
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1997, 42 (01): : 1 - 6
  • [6] DIRECT ELECTRON-TRANSFER REACTIONS BETWEEN IMMOBILIZED CYTOCHROME-C AND MODIFIED GOLD ELECTRODES
    COOPER, JM
    GREENOUGH, KR
    MCNEIL, CJ
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 347 (1-2): : 267 - 275
  • [7] Electron transfer principles in amperometric biosensors: Direct electron transfer between enzymes and electrode surface
    Lotzbeyer, T
    Schuhmann, W
    Schmidt, HL
    SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) : 50 - 54
  • [8] AMPEROMETRIC GLUCOSE BIOSENSORS BASED ON REDOX POLYMER-MEDIATED ELECTRON-TRANSFER
    HALE, PD
    BOGUSLAVSKY, LI
    INAGAKI, T
    KARAN, HI
    LEE, HS
    SKOTHEIM, TA
    OKAMOTO, Y
    ANALYTICAL CHEMISTRY, 1991, 63 (07) : 677 - 682
  • [9] Biosensors based on novel peroxidases with improved properties in direct and mediated electron transfer
    Lindgren, A
    Ruzgas, T
    Gorton, L
    Csöregi, E
    Ardila, GB
    Sakharov, IY
    Gazaryan, IG
    BIOSENSORS & BIOELECTRONICS, 2000, 15 (9-10): : 491 - 497
  • [10] Hydrogen peroxide biosensors based on direct electron transfer from plant peroxidases immobilized on self-assembled thiol-monolayer modified gold electrodes
    Gaspar, S
    Zimmermann, H
    Gazaryan, I
    Csöregi, E
    Schuhmann, W
    ELECTROANALYSIS, 2001, 13 (04) : 284 - 288