EFFECTS OF FREQUENCY, TIDAL VOLUME, AND LUNG-VOLUME ON CO2 ELIMINATION IN DOGS BY HIGH-FREQUENCY (2-30 HZ), LOW TIDAL VOLUME VENTILATION

被引:158
|
作者
SLUTSKY, AS
KAMM, RD
ROSSING, TH
LORING, SH
LEHR, J
SHAPIRO, AH
INGRAM, RH
DRAZEN, JM
机构
[1] HARVARD UNIV,SCH PUBL HLTH,DEPT PHYSIOL,BOSTON,MA 02115
[2] MIT,DEPT MECH ENGN,BOSTON,MA 02115
[3] W ROXBURY VET ADM HOSP,BOSTON,MA 02115
[4] HARVARD UNIV,SCH MED,BOSTON,MA 02115
来源
JOURNAL OF CLINICAL INVESTIGATION | 1981年 / 68卷 / 06期
关键词
D O I
10.1172/JCI110400
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
引用
收藏
页码:1475 / 1484
页数:10
相关论文
共 50 条
  • [1] A COMPARISON OF THE EFFECTS OF HIGH-FREQUENCY LOW TIDAL VOLUME AND LOW-FREQUENCY HIGH TIDAL VOLUME MECHANICAL VENTILATION
    BOROS, SJ
    CAMPBELL, K
    [J]. JOURNAL OF PEDIATRICS, 1980, 97 (01): : 108 - 112
  • [2] CO2-ELIMINATION DURING HIGH-FREQUENCY VENTILATION WITH REGARD TO LUNG-VOLUME
    MUTZ, N
    BAUM, M
    BENZER, H
    LOSERT, U
    [J]. INTENSIVE CARE MEDICINE, 1983, 9 (04) : 176 - 176
  • [3] EFFECTS OF SUPERIMPOSED SLOW OSCILLATORY FLOW ON CO2 REMOVAL BY LOW TIDAL VOLUME HIGH-FREQUENCY VENTILATION (HFV) IN DOGS
    GAVRIELY, N
    SOLWAY, J
    DRAZEN, JM
    SLUTSKY, A
    [J]. FEDERATION PROCEEDINGS, 1984, 43 (03) : 507 - 507
  • [4] A COMPARISON OF THE EFFECTS OF HIGH-FREQUENCY LOW TIDAL VOLUME AND LOW-FREQUENCY HIGH TIDAL VOLUME MECHANICAL VENTILATION - THE SIGNIFICANCE OF MEAN AIRWAY PRESSURE
    BOROS, SJ
    CAMPBELL, KR
    [J]. JOURNAL OF PEDIATRICS, 1980, 96 (06): : 1119 - 1119
  • [5] TIDAL VOLUME AND FREQUENCY-DEPENDENCE OF CARBON-DIOXIDE ELIMINATION BY HIGH-FREQUENCY VENTILATION
    ROSSING, TH
    SLUTSKY, AS
    LEHR, JL
    DRINKER, PA
    KAMM, R
    DRAZEN, JM
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1981, 305 (23): : 1375 - 1379
  • [6] LUNG-VOLUME RECRUITMENT DURING HIGH-FREQUENCY VENTILATION
    BRYAN, AC
    [J]. JOURNAL OF PEDIATRICS, 1990, 116 (02): : 317 - 317
  • [7] CO2 ELIMINATION AS A FUNCTION OF FREQUENCY AND TIDAL VOLUME IN RABBITS DURING HFO
    WATSON, JW
    JACKSON, AC
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1984, 57 (02) : 354 - 359
  • [8] MEASUREMENT OF TIDAL VOLUME DURING HIGH-FREQUENCY JET VENTILATION
    WEISBERGER, SA
    CARLO, WA
    FOUKE, JM
    CHATBURN, RL
    TILLANDER, T
    MARTIN, RJ
    [J]. PEDIATRIC RESEARCH, 1986, 20 (01) : 45 - 48
  • [9] TIDAL VOLUME AND AIRWAY PRESSURE ON HIGH-FREQUENCY JET VENTILATION
    CARLON, GC
    RAY, C
    GRIFFIN, J
    MIDOWNIK, S
    GROEGER, JS
    [J]. CRITICAL CARE MEDICINE, 1983, 11 (02) : 83 - 86
  • [10] INFLUENCE OF VENILATOR RATE AND INSPIRATORY TIME (TI) ON TIDAL VOLUME (VT), RATE OF CO2 ELIMINATION (VECO2) AND LUNG-VOLUME (LV) USING THE BUNNELL LIFE PULSE HIGH-FREQUENCY VENTILATOR
    SMITH, DW
    FRANKEL, LR
    ARIAGNO, RL
    [J]. PEDIATRIC PULMONOLOGY, 1987, 3 (05) : 377 - 377