INVESTIGATION OF THE EXTRACTED H- CURRENT IN A CONTINUOUSLY PULSED-VOLUME NEGATIVE-ION SOURCE

被引:6
|
作者
HEEREN, RMA [1 ]
MELLON, KN [1 ]
HOPKINS, MB [1 ]
CIRIC, D [1 ]
KLEYN, AW [1 ]
机构
[1] DUBLIN CITY UNIV,DEPT PHYS,DUBLIN 9,IRELAND
来源
EUROPHYSICS LETTERS | 1992年 / 17卷 / 6BIS期
关键词
ION SOURCES; POSITIVE NEGATIVE AND POLARIZED; ELEMENTARY PROCESSES IN PLASMA;
D O I
10.1209/0295-5075/17/6/005
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We have observed a significant increase in average extracted negative-ion current <I-> when pulsing the discharge current of a small, high-power density volume negative-ion source at low pressures. Compared to a DC-operated discharge, <I-> is increased by 35% at a pressure of 0.38 Pa. This result is explained with a simple model which shows that the enhancement of <I-> at low pressures can be attributed to an increased production of negative ions through dissociative attachment, as a result of the colder electrons in the postdischarge. The temporal behaviour of the extracted negative-ion current in this small, high-power density source is markedly different than the negative-ion current of a larger low-power density source.
引用
收藏
页码:503 / 508
页数:6
相关论文
共 50 条
  • [1] SPATIAL VARIATION OF NEGATIVE-ION DENSITY IN A VOLUME H- ION-SOURCE
    DEVYNCK, P
    BACAL, M
    BRUNETEAU, J
    HILLION, F
    REVUE DE PHYSIQUE APPLIQUEE, 1987, 22 (08): : 753 - 759
  • [2] IDENTIFICATION OF CESIUM EFFECTS ON ENHANCEMENT OF H- PRODUCTION IN A VOLUME NEGATIVE-ION SOURCE
    FUKUMASA, O
    TANEBE, T
    NAITOU, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (04): : 1213 - 1215
  • [3] NEGATIVE-ION SOURCE TESTS FOR H- INJECTION AT THE BROOKHAVEN AGS
    BARTON, DS
    WITKOVER, RL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (03) : 2681 - 2683
  • [4] NEGATIVE-ION SOURCE TESTS FOR H- INJECTION AT THE BROOKHAVEN AGS
    BARTON, DS
    WITKOVER, RL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (02): : 128 - 128
  • [5] CHARACTERISTICS OF THE NEGATIVE-ION BEAM EXTRACTED FROM AN LBL MULTICUSP VOLUME SOURCE
    DEBIAK, TW
    SOLENSTEN, L
    SREDNIAWSKI, JJ
    NG, YC
    HEUER, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (01): : 392 - 394
  • [6] Plasma electrode bias effect on the H- negative-ion density in an electron cyclotron resonance volume source
    Svarnas, Panagiotis
    Breton, Jacques
    Bacal, Marthe
    Faulkner, Ronan
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2007, 35 (04) : 1156 - 1162
  • [7] THE SUPPRESSION OF ELECTRONS EXTRACTED FROM A NEGATIVE-ION SOURCE
    LEA, LM
    HOLMES, AJT
    THORNTON, MF
    NAYLOR, GOR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (01): : 409 - 411
  • [8] STUDY OF PULSED DISCHARGE OPERATION OF VOLUME H- ION-SOURCE
    MICHAUT, C
    BACAL, M
    BELCHENKO, YI
    AUVRAY, J
    KONIECZNY, C
    STEPHAN, JP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (04): : 1207 - 1209
  • [9] Modeling of negative ion transport in hydrogen ion sources -: Estimation of extracted H- current
    Fukumasa, O
    Fujioka, T
    Fukuchi, T
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS, 2002, 639 : 75 - 81
  • [10] A 14-CMX36-CM VOLUME NEGATIVE-ION SOURCE PRODUCING MULTI-AMPERE H- ION-BEAMS
    HANADA, M
    INOUE, T
    KOJIMA, H
    MATSUDA, Y
    OHARA, Y
    OKUMURA, Y
    WATANABE, K
    SEKI, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (01): : 499 - 501