Performance Comparison of Four Commercial GE Discovery PET/CT Scanners: A Monte Carlo Study Using GATE

被引:0
|
作者
Geramifar, Parham [1 ,3 ,4 ]
Ay, Mohammad Reza [2 ,3 ,4 ]
Zafarghandi, Mojtaba Shamsaie [1 ]
Loudos, George [5 ]
Rahmim, Arman [6 ]
机构
[1] Amirkabir Univ Technol, Fac Nucl Engn & Phys, Tehran, Iran
[2] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[3] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran, Iran
[4] Univ Tehran Med Sci, Res Inst Nucl Med, Tehran, Iran
[5] Technol Educ Inst, Dept Med Instruments Technol, Athens, Greece
[6] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD USA
来源
IRANIAN JOURNAL OF NUCLEAR MEDICINE | 2009年 / 17卷 / 02期
关键词
Positron emission tomography (PET); Scanner performance; GATE;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner performances on an objective basis. In this study we evaluate and compare the performance of 4 Commercial GE PET/CT cameras, the (i) BGO-based Discovery LS PET/CT (DLS), (ii) the BGO-based Discovery ST PET/CT (DST), (iii) the BGO-based Discovery STE PET/CT (DSTE) and finally (iv) the LYSO-based Discovery RX PET/CT (DRX) scanner using the Geant4 Application for Tomographic Emission (GATE). GATE is an open source Monte Carlo simulation platform developed for PET and SPECT studies and is supported by the OpenGATE collaboration. In accordance with the National Electrical Manufactures Association (NEMA) NU 2-2001 protocols, the validation of models is carried out against actual published measurements and the performance comparison is done for sensitivity, scatter fraction and count rate performance, showing very similar performance compared with published results, thus enabling investigations to better model system performance (e.g. resolution degradation) within the reconstruction task.. The simulated results demonstrate highest sensitivity performance with the DST (though with the highest scatter fraction), and highest NECR performance for the LYSO-based DRX, The results also show that DRX, DLS and DSTE PET/CT cameras have nearly the same amount of scatter fraction.
引用
收藏
页码:26 / 33
页数:8
相关论文
共 50 条
  • [1] Monte Carlo Based Performance Assessment of Four Commercial GE Discovery PET/CT Scanners Using GATE
    Geramifar, P.
    Ay, M. R.
    Shamsaie, M.
    Loudos, G.
    Rahmim, A.
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3270 - +
  • [2] Validation of GATE Monte Carlo simulations of the GE Advance/Discovery LS PET scanners
    Schmidtlein, CR
    Kirov, AS
    Nehmeh, SA
    Erdi, YE
    Humm, JL
    Amols, HI
    Bidaut, LM
    Ganin, A
    Stearns, CW
    McDaniel, DL
    Hamacher, KA
    [J]. MEDICAL PHYSICS, 2006, 33 (01) : 198 - 208
  • [3] Monte Carlo Simulation of The GE LYSO-Based Discovery RX PET/CT Scanner Using GATE: a Validation Study
    Geramifar, P.
    Ay, M. R.
    Zafarghandi, M. Shamsaii
    Loudos, G.
    Rahmim, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S175 - S176
  • [4] Monte Carlo-based evaluation of inter-crystal scatter and penetration in the PET subsystem of three GE Discovery PET/CT scanners
    Zeraatkar, N.
    Ay, M. R.
    Ghafarian, P.
    Sarkar, S.
    Geramifar, P.
    Rahmim, A.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 659 (01): : 508 - 514
  • [5] GATE Monte Carlo Simulation of GE Discovery 600 and a Uniformity Phantom
    Sheen, Heesoon
    Im, Ki Chun
    Choi, Yong
    Shin, Hanback
    Han, Youngyih
    Chung, Kwangzoo
    Cho, Junsang
    Ahn, Sang Hee
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (11) : 1802 - 1808
  • [6] GATE Monte Carlo simulation of GE Discovery 600 and a uniformity phantom
    Heesoon Sheen
    Ki Chun Im
    Yong Choi
    Hanback Shin
    Youngyih Han
    Kwangzoo Chung
    Junsang Cho
    Sang Hee Ahn
    [J]. Journal of the Korean Physical Society, 2014, 65 : 1802 - 1808
  • [7] Monte Carlo simulation of two Siemens Biograph PET/CT system using GATE: Image quality performance
    Saaidi, Rahal
    Zeghari, Abdelkrim
    El Moursli, Rajaa Cherkaoui
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2024, 218
  • [8] Normalization of Monte Carlo PET data using GATE
    Pepin, Audrey
    Stute, Simon
    Jan, Sebastien
    Comtat, Claude
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4196 - 4200
  • [9] Count rate performance of brain-dedicated PET scanners: a Monte Carlo simulation study
    Teimoorisichani, Mohammadreza
    Goertzen, Andrew L.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21):
  • [10] A Monte Carlo simulation study of the impact of novel scintillation crystals on performance characteristics of PET scanners
    Ghabrial, Amir
    Franklin, Daniel
    Zaidi, Habib
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 50 : 37 - 45