IN-SITU CRYOFIXATION OF KIDNEY FOR ELECTRON-PROBE X-RAY-MICROANALYSIS

被引:0
|
作者
FREUDENRICH, CC
HOCKETT, D
INGRAM, P
LEFURGEY, A
机构
[1] DUKE UNIV, MED CTR, DEPT CELL BIOL, DIV PHYSIOL, DURHAM, NC 27710 USA
[2] DUKE UNIV, SCH ENVIRONM, DURHAM, NC 27706 USA
[3] RES TRIANGLE INST, RES TRIANGLE PK, NC 27709 USA
[4] VET AFFAIRS MED CTR, DURHAM, NC 27705 USA
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Cell physiological and pathophysiological studies often require information about the elemental composition of intracellular organelles in situ. Electron probe X-ray microanalysis (EPXMA) is one of the few methods by which intracellular elemental content and distribution can be measured simultaneously. While several cryofixation techniques for EPXMA have been utilized on isolated cells, few have been applied successfully to whole tissue in vivo or in, situ. A recently developed, commercial, portable, metal-mirror device was used for preserving kidney in situ to determine the intracellular element distribution in proximal tubule cells. Kidneys of male rats were exposed, cryofixed, and analyzed for organelle elemental contents by EPXMA imaging. In addition, some portions of the frozen tissue were prepared for conventional transmission electron microscopy. Proximal tubules were preserved with intact brush borders and open lumens. The quality of preservation of tubule cell organelles varied inversely as a function of depth from the point of first contact with the mirror surface; the best preservation was within 15 mu m, while the poorest preservation was deeper than 30 mu m. Analysis of EPXMA images from the best-preserved regions revealed that proximal tubule cell cytoplasmic K/Na was similar to 6, cytoplasmic Cl was low relative to other subcellular compartments, and mitochondrial Ca levels were 1.8 nmole/mg dry weight; these observations indicate that the cells were physiologically viable at the time of cryofixation. The advantages of in situ cryofixation by this metal-mirror method include acquisition of organelle elemental content data in vivo, ease of use, reproducibility, portability, applicability to other tissues, and suitability for pathophysiological studies. (C) 1994 Academic Press, Inc.
引用
收藏
页码:173 / 182
页数:10
相关论文
共 50 条
  • [1] ELECTRON-PROBE X-RAY-MICROANALYSIS
    CANTINO, ME
    HUTCHINSON, TE
    TRENDS IN BIOCHEMICAL SCIENCES, 1982, 7 (04) : 132 - 134
  • [2] QUANTITATIVE ELECTRON-PROBE X-RAY-MICROANALYSIS IN BIOLOGY
    HALL, TA
    SCANNING MICROSCOPY, 1989, 3 (02) : 461 - 466
  • [3] ELECTRON-PROBE X-RAY-MICROANALYSIS OF PHOTOSENSITIVE MATERIALS
    KUROSAKI, K
    JOURNAL OF ELECTRON MICROSCOPY, 1982, 31 (01): : 102 - 102
  • [4] RECENT ADVANCES IN ELECTRON-PROBE X-RAY-MICROANALYSIS
    VANBORM, WA
    ADAMS, FC
    ANALYTICA CHIMICA ACTA, 1989, 218 (02) : 185 - 215
  • [5] ELECTRON-PROBE X-RAY-MICROANALYSIS OF BIOLOGICAL TISSUE
    SMITH, NKR
    CAMERON, IL
    BIOTECHNIQUES, 1987, 5 (04) : 332 - &
  • [6] ELECTRON-PROBE X-RAY-MICROANALYSIS OF RABBIT CILIARY EPITHELIUM
    CIVAN, MM
    BOWLER, JM
    ZELLHUBERMCMILLAN, S
    PEART, D
    CARRE, DA
    PURVES, RD
    MACKNIGHT, ADC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 978 - 978
  • [7] ELECTRON-PROBE X-RAY-MICROANALYSIS OF ARSENIC INCLUSIONS IN FISH
    SORENSEN, EMB
    SMITH, NKR
    RAMIREZMITCHELL, R
    ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1982, 11 (04) : 469 - 473
  • [8] ELECTRON-PROBE X-RAY-MICROANALYSIS OF BACTERIAL-DNA
    SIGEE, DC
    ELMASRY, MH
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1987, 15 (3-4): : 215 - 227
  • [9] CADMIUM CONCENTRATION BY THE LYSOSOMES - ELECTRON-PROBE X-RAY-MICROANALYSIS
    CHASSARDBOUCHAUD, C
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE III-SCIENCES DE LA VIE-LIFE SCIENCES, 1981, 293 (05): : 261 - +
  • [10] ELECTRON-PROBE X-RAY-MICROANALYSIS OF CRYOSECTIONED NORMAL AND HYPOXIC MYOCARDIUM
    BURTON, KP
    HAGLER, HK
    LOPEZ, LE
    GREICO, CA
    SWICK, RL
    WILLERSON, JT
    BUJA, LM
    FEDERATION PROCEEDINGS, 1981, 40 (03) : 759 - 759