摘要
Background: Permanent polymers in first generation drug-eluting stent (DES) have been imputed to be a possible cause of persistent inflammation, remodeling, malapposition and late stent thrombosis. We aim to describe the in vivo experimental result of a new polymer-free DES eluting sirolimus from stent-plus-balloon (Focus np stent, Envision Scientific) compared with a bare-metal stent (BMS) (Amazonia CroCo, Minvasys) and with a biolimus A9 eluting stent (Biomatrix, Biosensors). Methods: In 10 juvenile pigs, 23 coronary stents were implanted in the coronary arteries (8 Amazonia CroCo, 8 Focus np, and 7 Biomatrix). At 28-day follow-up, optical coherence tomography (OCT) and histology were used to evaluate neointimal hyperplasia and healing response. Results: According to OCT analysis, Focus np stents had a greater lumen area and less neointimal hyperplasia response than BMS and Biomatrix had. Histomorphometry results showed less neointimal hyperplasia in Focus np than in BMS. Histology showed a higher fibrin deposition in Biomatrix stent compared to Focus np and BMS. Conclusions: The new polymer-free DES with sirolimus eluted from stent-plus-balloon demonstrated safety and reduced neointimal proliferation compared with the BMS and Biomatrix stents at 28-day follow-up in this porcine coronary model. This new polymer-free DES is promising and warrants further clinical studies.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 50 条
  • [1] Restenosis in a Bare-Metal Stent: Drug-Eluting Balloon or Drug-Eluting Stent?
    Colombo, Antonio
    Jabbour, Richard J.
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (04)
  • [2] In vivo comparison of a polymer-free Biolimus A9-eluting stent with a biodegradable polymer-based Biolimus A9 eluting stent and a bare metal stent in balloon denuded and radiated hypercholesterolemic rabbit iliac arteries
    Waksman, Ron
    Pakala, Rajbabu
    Baffour, Richard
    Seabron, Rufus
    Hellinga, David
    Chan, Rosanna
    Su, Shih-Horng
    Kolodgie, Frank
    Virmani, Renu
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (03) : 429 - 436
  • [3] Drug-eluting stent implantation for the treatment of bare-metal or drug-eluting stent restenosis
    Nezuo, Shintaro
    Okura, Hiroyuki
    Fukuhara, Kenzo
    Kume, Teruyoshi
    Hayashida, Akihiro
    Neishi, Yoji
    Kawamoto, Takahiro
    Yoshida, Kiyoshi
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B183 - B183
  • [4] BioMatrix® Biolimus A9®-eluting coronary stent:: a next-generation drug-eluting stent for coronary artery disease
    Grube, Eberhard
    Buellesfeld, Lutz
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (06) : 731 - 741
  • [5] Efficacy of Drug-Eluting Balloon in Patients with Bare-Metal or Drug-Eluting Stent Restenosis
    Berta, Balazs
    Jambrik, Zoltan
    Kohar, Krisztina
    Szabo, Gyorgy
    Ruzsa, Zoltan
    Molnar, Levente
    Barczi, Gyorgy
    Geller, Laszlo
    Becker, David
    Merkely, Bela
    [J]. HELLENIC JOURNAL OF CARDIOLOGY, 2014, 55 (05) : 369 - 377
  • [6] A Randomized Comparison of Drug-Eluting Balloon Versus Everolimus-Eluting Stent in Patients With Bare-Metal Stent-In-Stent Restenosis
    Alfonso, Fernando
    Jose Perez-Vizcayno, Maria
    Cardenas, Alberto
    Garcia del Blanco, Bruno
    Seidelberger, Bernhard
    Iniguez, Andres
    Gomez-Recio, Manuel
    Masotti, Monica
    Teresa Velazquez, M.
    Sanchis, Juan
    Garcia-Touchard, Arturo
    Zueco, Javier
    Bethencourt, Armando
    Melgares, Rafael
    Cequier, Angel
    Dominguez, Antonio
    Mainar, Vicente
    Lopez-Minguez, Jose R.
    Moreu, Jose
    Marti, Vicens
    Moreno, Raul
    Jimenez-Quevedo, Pilar
    Gonzalo, Nieves
    Fernandez, Cristina
    Macaya, Carlos
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (14) : 1378 - 1386
  • [7] Repeated Sirolimus-Eluting Stent Implantation to Treat Sirolimus-Eluting Stent and Bare-Metal Stent Restenosis
    Nishihira, Kensaku
    Shibata, Yoshisato
    Ishikawa, Tetsunori
    Nomura, Katsumasa
    Nakama, Tatsuya
    Mine, Daigo
    Inoue, Yohei
    Ashikaga, Keiichi
    Kuriyama, Nehiro
    Matsuyama, Akihiko
    Imamura, Takuroh
    Asada, Yujiro
    Kitamura, Kazuo
    [J]. CIRCULATION JOURNAL, 2010, 74 (11) : 2329 - 2333
  • [9] Efficacy and safety of drug-eluting stent implantation for the treatment of in-stent restenosis occurring within bare-metal stent and drug-eluting stent
    Heng Ge
    Qing Zhang
    Wei Zhou
    Qing He
    Zhi-hua Han
    Ben He
    [J]. Journal of Zhejiang University SCIENCE B, 2010, 11 : 553 - 560
  • [10] Efficacy and safety of drug-eluting stent implantation for the treatment of in-stent restenosis occurring within bare-metal stent and drug-eluting stent
    Ge, Heng
    Zhang, Qing
    Zhou, Wei
    He, Qing
    Han, Zhi-hua
    He, Ben
    [J]. JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2010, 11 (08): : 553 - 560