OPTIMUM OPERATION MANAGEMENT EFFECT OF MAIN SEWAGE PUMPING STATIONS ON TRUNK SEWER DETERIORATION

被引:0
|
作者
Khudair, Basim H. [1 ]
Jbbar, Rehab K. [1 ]
机构
[1] Univ Baghdad, Engn Coll, Jadiriyah Campus, Baghdad, Iraq
关键词
Hydraulic analysis; Operational performance evaluation; Pumps condition; Sewage pumping stations; Trunk sewer deterioration;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Sewage pumping stations are considered an important part of any sewerage system. Pumps failure in these stations means that the pumps are unable to work at the design requirement (flow capacity and head) and that may cause sewer overflow and flooding leading to sewer deterioration. In this paper, two main sewage pumping stations in Baghdad city were selected as case studies, Al-Habibia and Al-Ghazali located on Zublin trunk sewer 3000 mm and Baghdad trunk sewer 1200-2100 respectively. This study focused mainly on the operation of main sewage pumping stations and their effect, both directly and indirectly, on changing hydraulic properties, which leads to an increase in the deterioration of sewage pipes. The hydraulic analysis was conducted to investigate the effect of the operational performance of these stations on the deterioration of the trunk sewers. In general, the sewage pumps are in good condition based on the completed evaluation of these stations but, it was observed that Al-Habibia sewage pumping station was unable to discharge high sewage flow (d/D = 0.75). Backup flow occurred in the inlet sewer and caused overflow and flooding. The hydraulic analysis for the effluent sewer showed that the actual flowing velocities of the operating conditions examined were greater than the minimum self-cleaning velocity. Al-Ghazali sewage pumping station was able to receive the influent sewage for all the cases of flow (low, medium and high). While the effluent sewer (Baghdad trunk sewer) that was 70% filled with sediments, that reduced its capacity, does not work with the high discharges of the pumps. Therefore, resulting in sewage flows from this overloaded sewer onto the streets and harms the environment.
引用
收藏
页码:4094 / 4103
页数:10
相关论文
共 7 条
  • [1] Framework for Enhanced Stormwater Management by Optimization of Sewer Pumping Stations
    Ganora, D.
    Isacco, S.
    Claps, P.
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING, 2017, 143 (08)
  • [2] MODELING AND CONTROL OF SEWER FLOW FOR REDUCED COST OPERATION OF A SEWAGE PUMPING STATION
    TAN, PC
    DABKE, KP
    MEIN, RG
    [J]. IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1988, 18 (05): : 807 - 813
  • [3] COMPRESSORS, PUMPS, AND PIPELINE FITTINGS SELECTION OF OPTIMUM PARAMETERS OF PUMPING EQUIPMENT AT TRUNK PIPELINE OIL PUMPING STATIONS
    Gasparyants, R. S.
    Shcherbatenko, I. V.
    Levchenko, I. L.
    [J]. CHEMICAL AND PETROLEUM ENGINEERING, 2009, 45 (7-8) : 427 - 437
  • [4] Event-driven model predictive control of sewage pumping stations for sulfide mitigation in sewer networks
    Liu, Yiqi
    Ganigue, Ramon
    Sharma, Keshab
    Yuan, Zhiguo
    [J]. WATER RESEARCH, 2016, 98 : 376 - 383
  • [5] PREDICTION OF INFLUENT FLOW INTO SEWER PUMPING STATION FOLLOWED BY QUASI-OPTIMUM SCHEDULING OF PUMP OPERATION
    SHIOYA, M
    SHIRAISHI, A
    KATO, S
    [J]. PROGRESS IN WATER TECHNOLOGY, 1978, 9 (5-6): : 343 - 347
  • [6] OPTIMAL MANAGEMENT OF WATER RESOURCES IN LARGE MAIN CANALS WITH CASCADE PUMPING STATIONS
    Kabulov, Anvar
    Normatov, Ibrokhimali
    Seytov, Aybek
    Kudaybergenov, Adilbay
    [J]. 2020 IEEE INTERNATIONAL IOT, ELECTRONICS AND MECHATRONICS CONFERENCE (IEMTRONICS 2020), 2020, : 187 - 190
  • [7] MANAGEMENT OF THE QUALITY OF THE RIVER SOAR .1. THE EFFECT ON DESIGN AND OPERATION OF WANLIP SEWAGE-TREATMENT WORKS
    UPTON, J
    BREWIN, D
    [J]. WATER POLLUTION CONTROL, 1987, 86 (01): : 67 - 73