Repair Using Conventional Implant for Ruptured Annulus Fibrosus after Lumbar Discectomy: Surgical Technique and Case Series

被引:15
|
作者
Suh, Bo-Gun [1 ,2 ]
Uh, Jae-Hyung [1 ,2 ]
Park, Sang-Hyuk [1 ,3 ]
Lee, Gun Woo [4 ]
机构
[1] Pohang Semyeng Christianty Hosp, Spine Ctr, Pohang, South Korea
[2] Pohang Semyeng Christianty Hosp, Dept Orthopaed Surg, Pohang, South Korea
[3] Pohang Semyeng Christianty Hosp, Dept Neurosurg, Pohang, South Korea
[4] Armed Forces Yangju Hosp, Dept Orthopaed Surg, 461 Yongam Ri, Yangju, South Korea
关键词
Annulus fibrosus; Repair; Intervertebral disc displacement; Lumbar vertebrae;
D O I
10.4184/asj.2015.9.1.14
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: A retrospective review of annulus fibrosus repair (AR) using a novel technique with a conventional implant. Purpose: The purpose of this study was to present the feasibility and clinico-radiological outcomes of a novel AR technique using a conventional implant to minimize recurrence following a lumbar discectomy (LD). Overview of Literature: Conventional repair techniques to prevent recurrence following LD have several drawbacks. The AR surgical technique has received little attention as an adjunct to LD. Methods: A total of 19 patients who underwent novel AR following LD, and who were available for follow-up for at least three years, were enrolled in this study. Several variables, including the type and size of disc herniation, and the degree of disc degeneration, were evaluated preoperatively. Postoperatively, the presence of clinical and radiological recurrence of disc herniation was evaluated from pain intensity and functional statuses, as well as an enhanced L-spine magnetic resonance imaging at the final follow-up. The presence of a peripheral hollow rim and inserted anchor mobilization were also evaluated during the follow-up. Results: During follow-ups, there were no recurrences of disc herniation or complications, including neurovascular complications. Pain and functional disability improved significantly after surgery, and the improvement was maintained throughout the three-year follow-up period. No mobilization or implant peripheral hollow rim was observed during the follow-up. Conclusions: This study examined the feasibility of a novel and easily available annulus implant technique following LD. These results suggest performing AR with this technique may be a valuable alternative for optimizing outcomes, if the procedure is performed in proper candidates.
引用
收藏
页码:14 / 21
页数:8
相关论文
共 50 条
  • [21] Implant Survival after Preparation of the Implant Site Using a Single Bur: A Case Series
    Bettach, Raphael
    Taschieri, Silvio
    Boukhris, Gilles
    Del Fabbro, Massimo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (01) : 13 - 21
  • [22] Transforaminal endoscopic lumbar discectomy with targeted puncture and foraminotomy for very highly migrated disc herniation: A technique note with case series
    Shen, Jun-Jie
    Wang, Xin
    Cai, Bin
    Chen, Yuan-Yuan
    Zhang, Guo-Wang
    Xu, Jian-Guang
    Lian, Xiao-Feng
    HELIYON, 2022, 8 (10)
  • [23] Recurrence mechanisms after inguinal hernia repair by the Onstep technique: a case series
    Oberg, S.
    Andresen, K.
    Hauge, D.
    Rosenberg, J.
    HERNIA, 2016, 20 (05) : 681 - 685
  • [24] Recurrence mechanisms after inguinal hernia repair by the Onstep technique: a case series
    S. Öberg
    K. Andresen
    D. Hauge
    J. Rosenberg
    Hernia, 2016, 20 : 681 - 685
  • [25] Gluteus Medius Repair using a Gluteus Maximus Flap Augmented with Synthetic Polyethylene Mesh: Surgical Technique and Case Series
    Jimenez-Telleria, Inigo
    Foruria, Xabier
    Moreta, Jesus
    Bernuy, Lucia
    Casado, Oscar
    Martinez-de los Mozos, Jose Luis
    ORTHOPEDIC REVIEWS, 2022, 14 (03)
  • [26] Risk Factors and Surgical Management of Recurrent Herniation after Full-Endoscopic Lumbar Discectomy Using Interlaminar Approach
    Ono, Koichiro
    Ohmori, Kazuo
    Yoneyama, Reiko
    Matsushige, Osamu
    Majima, Tokifumi
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [27] Achilles Tendon Reattachment after Surgical Treatment of Insertional Tendinosis Using the Suture Bridge Technique: A Case Series
    Witt, Bryan L.
    Hyer, Christopher F.
    JOURNAL OF FOOT & ANKLE SURGERY, 2012, 51 (04): : 487 - 493
  • [28] A Descriptive Case Series of Incisional Hernia Repair Using Dual Mesh Technique
    Theodorou, Chloe
    Moinuddin, Zia
    Van Dellen, David
    BRITISH JOURNAL OF SURGERY, 2021, 108
  • [29] Surgical Technique of Arthroscopic Transosseous Implant-Less Rotator Cuff Repair Using "Arthrocuff" System
    Rajagopalan, Senthilvelan
    Sridharan, Rajsirish Bellal
    Ravi, Nehru
    ARTHROSCOPY TECHNIQUES, 2022, 11 (05): : E833 - E839
  • [30] Comment to: Recurrence mechanisms after inguinal hernia repair by the Onstep technique: a case series
    G. G. Koning
    P. W. H. E. Vriens
    F. Berrevoet
    Hernia, 2017, 21 : 661 - 662