HIGH-RESOLUTION LIQUID-CHROMATOGRAPHY OF FLUORESCENT DYE-LABELED NUCLEIC-ACIDS

被引:38
|
作者
OEFNER, PJ
HUBER, CG
UMLAUFT, F
BERTI, GN
STIMPFL, E
BONN, GK
机构
[1] JOHANNES KEPLER UNIV, DEPT ANALYT CHEM, A-4040 LINZ, AUSTRIA
[2] UNIV INNSBRUCK, INST ANALYT CHEM & RADIOCHEM, A-6020 INNSBRUCK, AUSTRIA
[3] UNIV INNSBRUCK, DEPT INTERNAL MED, A-6020 INNSBRUCK, AUSTRIA
关键词
D O I
10.1006/abio.1994.1543
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Using 100 mM of triethylammonium acetate as ion-pairing reagent, phosphodiester oligonucleotides labeled fluorescently at their 5' terminus could be separated successfully on alkylated nonporous 2.3-mu m poly(styrene-divinylbenzene) particles by means of high-resolution liquid chromatography. Applying excitation wavelengths of 490, 520, 550, and 575 nm, respectively, optimum sensitivity was achieved for the fluorophores 5-carboxyfluorescein 2',7'-dimethoxy - 4',5' - dichloro - 6 - carboxyfluorescein, N,N,N',N'-tetramethyl-6-carboxyrhodamine and 6-carboxy-X-rhodamine (FAM, JOE, TAMRA, and ROX, respectively) at emission wavelengths of 520, 550, 580, and 605 nm, respectively. With calibration curves being linear over at least three orders of magnitude, the lower detection limits were 0.5, 2, 2, and 3 fmol, respectively. Depending on the type of fluorescent dye attached, retention times increased in the order JOE < FAM < TAMRA < ROX. Subsequently, fluorescent oligonucleotides were employed to prime polymerase chain reactions (PCR). Again the fluorophores were found to increase the retention times of double-stranded nucleic acids, but to a lesser degree than those of single-stranded oligonucleotides. Using a single FAM label attached to one of the two PCR primers, the sensitivity of fluorescence detection was found to be approximately 1 fmol or 30-70 times higher than that of uv absorbance detection depending on the length of the PCR product. Since the technique allows the separation of PCR products differing only 4 to 8 base pairs in length within a size range of 50 to 200 base pairs, it may be employed for the quantitative assessment of competitive PCR. (C) 1994 Academic Press, Inc.
引用
收藏
页码:39 / 46
页数:8
相关论文
共 50 条
  • [1] HIGH-RESOLUTION LIQUID-CHROMATOGRAPHY OF NUCLEIC-ACIDS
    OEFNER, PJ
    BONN, GK
    AMERICAN LABORATORY, 1994, 26 (09) : C28 - &
  • [2] RESOLUTION OF NUCLEIC-ACIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MCLAUGHLIN, LW
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1986, 5 (08) : 215 - 219
  • [3] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF COMPONENTS OF NUCLEIC-ACIDS
    TITKOVA, NF
    POMAZANOV, VV
    KALININ, YT
    SAKODYNSKII, KI
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1983, 38 (07): : 999 - 1011
  • [4] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY PURIFICATION OF NUCLEIC-ACIDS
    THOMPSON, JA
    BLAKESLEY, RW
    DNA-A JOURNAL OF MOLECULAR & CELLULAR BIOLOGY, 1983, 2 (01): : 69 - 69
  • [5] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY PURIFICATION OF NUCLEIC-ACIDS
    THOMPSON, JA
    BLAKESLEY, RW
    FEDERATION PROCEEDINGS, 1983, 42 (07) : 1953 - 1953
  • [6] CHARACTERIZATION OF NUCLEOTIDES AND NUCLEIC-ACIDS BY HIGH-PRESSURE LIQUID-CHROMATOGRAPHY
    KO, CY
    MCNAIR, HM
    VERCELLO.JR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1974, : 5 - 5
  • [7] Analysis of microliter volumes of dye-labeled nucleic acids
    Nagai, T
    Chapman, WH
    BIOTECHNIQUES, 2002, 32 (02) : 356 - +
  • [8] HIGH-RESOLUTION CHROMATOGRAPHY OF NUCLEIC-ACIDS ON THE GEN-PAK FAX COLUMN
    STOWERS, DJ
    KEIM, JMB
    PAUL, PS
    LYOO, YS
    MERION, M
    BENBOW, RM
    JOURNAL OF CHROMATOGRAPHY, 1988, 444 : 47 - 65
  • [9] HIGH-RESOLUTION LIQUID-CHROMATOGRAPHY
    AHUJA, S
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (8-9): : 1841 - 1845
  • [10] HIGH-RESOLUTION LIQUID-CHROMATOGRAPHY
    AHUJA, S
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (08): : 434 - 434