TOTAL CONTAINMENT OF A CONTINUOUS-FLOW ZONAL CENTRIFUGE

被引:2
|
作者
GOODERS, AP
WEBB, NL
ALLEN, GJ
RICHARDS, BM
机构
[1] Searle Research and Development, Lane End Road, High Wycombe, Bucks,HP12 4HL, United Kingdom
[2] Lancer, 1831 Olive Street, St. Louis,MO,63103, United States
[3] Radiochemical Centre, White Lion Road, Amersham, Bucks, United Kingdom
关键词
Ethylene;
D O I
10.1002/bit.260230102
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A continuous-flow, high throughput, turbine-driven zonal centrifuge has been contained for use with biologically hazardous materials. The centrifuge and all ancillary equipment are enclosed in three sealed cabinets that are maintained at negative pressure, decontaminated with ethylene oxide, and provide cooling for the process fluids. Sample handling is semiautomated and remotely controlled for ease of operation and includes an automated decontamination system. The centrifuge subsystems can be decontaminated prior to an engineer servicing the machine, and apparatus is provided for absolute filtration of the centrifuge turbine exhaust. © 1981 John Wiley & Sons, Inc.
引用
收藏
页码:1 / 18
页数:18
相关论文
共 50 条
  • [1] TOTAL CONTAINMENT OF A BATCH-TYPE ZONAL CENTRIFUGE
    WEBB, NL
    RICHARDS, BM
    GOODERS, AP
    BIOTECHNOLOGY AND BIOENGINEERING, 1975, 17 (09) : 1313 - 1322
  • [2] FLOW AND SEDIMENTATION IN CONTINUOUS-FLOW CENTRIFUGE
    REUTER, H
    CHEMIE INGENIEUR TECHNIK, 1967, 39 (5-6) : 311 - &
  • [3] FRACTIONAL CLEANOUT IN A CONTINUOUS-FLOW CENTRIFUGE
    SARTORY, WK
    SEPARATION SCIENCE, 1970, 5 (02): : 137 - &
  • [4] IMPROVED GRANULOCYTE PROCUREMENT WITH CONTINUOUS-FLOW CENTRIFUGE
    CLIFT, RA
    BUCKNER, CD
    WILLIAMS, BM
    HICKMAN, RO
    THOMAS, ED
    TRANSFUSION, 1973, 13 (05) : 276 - 282
  • [5] A CONTINUOUS-FLOW CENTRIFUGE FOR CONCENTRATION OF SCHISTOSOME CERCARIAE
    OLIVIER, LJ
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 1966, 15 (6P1): : 875 - &
  • [6] RAPID PLASMA EXCHANGE WITH CONTINUOUS-FLOW CENTRIFUGE
    MCCULLOUGH, J
    FORTUNY, IE
    KENNEDY, BJ
    EDSON, JR
    BRANDA, RF
    JACOB, HS
    TRANSFUSION, 1973, 13 (02) : 94 - 99
  • [7] LEUKOCYTE COLLECTION BY AN IN VIVO CONTINUOUS-FLOW CENTRIFUGE
    FREIREICH, EJ
    JOURNAL OF CLINICAL INVESTIGATION, 1968, 47 (06): : A36 - +
  • [8] CALCULATION OF SUSPENSION FILTRATION IN A CONTINUOUS-FLOW CENTRIFUGE
    Semenov, E. V.
    Slavyanskii, A. A.
    Karamzin, A. V.
    CHEMICAL AND PETROLEUM ENGINEERING, 2015, 51 (7-8) : 509 - 514
  • [9] DESIGN AND CONSTRUCTION OF A VENTILATED CABINET FOR A CONTINUOUS-FLOW CENTRIFUGE
    EVANS, CGT
    HARRISSMITH, R
    STRATTON, JE
    MELLING, J
    BIOTECHNOLOGY AND BIOENGINEERING, 1974, 16 (12) : 1681 - 1687
  • [10] USE OF HEPARIN FOR CYTAPHERESIS AND PLASMAPHERESIS IN A CONTINUOUS-FLOW CENTRIFUGE
    MORALES, M
    PIZZUTO, J
    REYNA, M
    AMBRIZ, R
    AVILES, A
    CONTE, G
    SINCO, A
    TRANSFUSION, 1982, 22 (05) : 384 - 387