A LASER-AIDED PREALIGNED PINHOLE COLLIMATOR FOR SYNCHROTRON X-RAYS

被引:50
|
作者
CHU, B [1 ]
HARNEY, PJ [1 ]
LI, YJ [1 ]
KUNG, LL [1 ]
YEH, FJ [1 ]
HSIAO, BS [1 ]
机构
[1] DUPONT CO INC, DEPT FIBERS, EXPTL STN, WILMINGTON, DE 19880 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1994年 / 65卷 / 03期
关键词
D O I
10.1063/1.1145123
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A pinhole small-angle x-ray scattering (SAXS) instrument was constructed at the SUNY X3A2 beamline, National Synchrotron Light Source, Brookhaven National Laboratory. The three pinholes were mounted in a thick-walled stainless steel pipe and prealigned by using a portable laser source and a charge-coupled device (CCD) area detector. After the prealignment, incorporation of the collimator to the synchrotron x-ray source required only maximization of the incident x-ray intensity passing through the pinholes, which could be done easily by using a scintillation counter after proper attenuation. The entire synchrotron SAXS instrument setup took only a few hours even without stepping motor control for the pinhole collimator unit. By combining this collimator with a CCD-based x-ray area detector which could be assembled by using commercially available components, the SAXS instrument showed good performance for structural scales up to an order of 100 nm. The CCD-based x-ray area detector used a computer(or manually) controlled intensified unit with a variable gain setting in order to accommodate the changing x-ray flux and to protect the detector from over exposure, a necessary feature for operation of an area detector at a synchrotron light source.
引用
收藏
页码:597 / 602
页数:6
相关论文
共 50 条
  • [1] COLLIMATOR FOR SOFT X-RAYS
    WRISTON, RS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1974, 45 (12): : 1566 - 1568
  • [2] Pinhole camera exposures with x-rays
    Siegl, K
    ANNALEN DER PHYSIK, 1915, 46 (08) : 1151 - 1152
  • [3] Pinhole interferometry with coherent hard X-rays
    Leitenberger, W
    Wendrock, H
    Bischoff, L
    Weitkamp, T
    JOURNAL OF SYNCHROTRON RADIATION, 2004, 11 : 190 - 197
  • [4] VERSATILE MONOCHROMATOR FOR SYNCHROTRON X-RAYS
    STAUDENMANN, JL
    SANDHOLM, M
    CHAPMAN, LD
    LIEDL, GL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 222 (1-2): : 177 - 179
  • [5] Studies of magnetism with synchrotron X-rays
    European Commission, Karlsruhe, Germany
    J Alloys Compd, 1 -2 pt 2 (544-551):
  • [6] Applications of synchrotron X-rays to radiotherapy
    Blattmann, H
    Gebbers, JO
    Bräuer-Krisch, E
    Bravin, A
    Le Duc, G
    Burkard, W
    Di Michiel, M
    Djonov, V
    Slatkin, DN
    Stepanek, J
    Laissue, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2): : 17 - 22
  • [7] Studies of magnetism with synchrotron X-rays
    Lander, GH
    JOURNAL OF ALLOYS AND COMPOUNDS, 1997, 250 (1-2) : 544 - 551
  • [8] Tabletop X-rays: Miniaturising the synchrotron
    Nathan, Stuart
    Engineer, 2010, 1-NOVEMBER
  • [9] Nuclear scattering of synchrotron X-rays
    Smirnov, GV
    X-RAY AND INNER-SHELL PROCESSES - 17TH INTERNATIONAL CONFERENCE, 1997, (389): : 323 - 350
  • [10] Chemical and biological applications of synchrotron and free electron laser X-rays
    Hodgson, Keith
    Hedman, Britt
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254