TUNNEL AND RESERVOIR PLAN SOLUTION TO CHICAGOS COMBINED SEWER OVERFLOW, BASEMENT FLOODING, AND POLLUTION

被引:1
|
作者
BERGMAN, WA
KAPADIA, DH
机构
[1] The Metropolitan Solitary District of Greater Chicago, Chicago, IL 60611, United States
关键词
Reservoirs; -; Chicago; Illinois - Runoff - Control - Sewage Treatment - Sewers - Combined - Tunnels and Tunneling - Chicago; Illinois;
D O I
10.1139/l88-054
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Each time rainfall exceeds 8.4 mm, the combined sewers' capacities are exceeded, and they discharge directly to the canal system on the average of 100 times per year without benefit of treatment. When the sewers and canal system are overtaxed, raw sewage backs up the sewers in Chicago and 51 suburbs, flooding streets, businesses, and home basements. In order to solve these problems on a regional basis, the Sanitary District in 1972 adopted the tunnel and reservoir plan (TARP). TARP is a second river system which is being constructed by boring tunnels up to 11 m in diameter in rock as much as 100 m under the city. When the surface sewers' capacities are exceeded, the excess flows will drop into TARP. Huge reservoirs totalling 157,000,000 m3 capacity will store the sewage until it can be gradually pumped back to the treatment works.
引用
收藏
页码:389 / 396
页数:8
相关论文
共 33 条
  • [1] BOTTLING RAINSTORMS - CHICAGOS TUNNEL AND RESERVOIR PLAN
    DALE, JT
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1978, 50 (08): : 1888 - 1892
  • [2] Combined sewer overflow control plan for Peoria
    Helm, Richard B.
    van Winkle, Stephen N.
    Public Works, 1992, 123 (03):
  • [3] Parsimonious Model for Combined Sewer Overflow Pollution
    Willems, Patrick
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2010, 136 (03): : 316 - 325
  • [4] Connecticut combined sewer overflow tunnel moves forward
    Rice, Justin
    ENR (Engineering News-Record), 2016, 275 (33):
  • [5] Deep Tunnel for Regulating Combined Sewer Overflow Pollution and Flood Disaster: A Case Study in Guangzhou City, China
    Wu, Haichun
    Huang, Guoru
    Meng, Qingqiang
    Zhang, Mingzhu
    Li, Licheng
    WATER, 2016, 8 (08)
  • [6] REDUCTION OF COMBINED SEWER OVERFLOW POLLUTION LOADS BY DETENTION OF SANITARY SEWAGE
    SCHILLING, W
    KOLLATSCH, DT
    WATER SCIENCE AND TECHNOLOGY, 1990, 22 (10-11) : 205 - 212
  • [7] Progress on Sewage Overflow Pollution Control Technology of Combined Sewer System
    Gu, Yaming
    Xie, Qingjie
    Yin, Hailong
    Kang, Su
    Wu, Qiumin
    2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 1957 - 1962
  • [8] Design begins of Detroit's combined sewer overflow solution
    Landers, J
    CIVIL ENGINEERING, 2006, 76 (04): : 26 - 26
  • [9] Modeling of Transient Pneumatic Events in a Combined Sewer Overflow Storage Tunnel System
    Klaver, Peter
    Collins, David
    Robinson, Kurt
    Bell, Scott
    JOURNAL OF WATER MANAGEMENT MODELING, 2016, 25
  • [10] Atlanta West Area Combined Sewer Overflow Storage Tunnel and pumping station
    Divito, RC
    Klecan, W
    Barnes, GD