EVALUATION OF ACCURACY AND PRECISION OF ENUMERATING AEROBIC HETEROTROPHS IN WATER SAMPLES BY SPREAD PLATE METHOD

被引:25
|
作者
KAPER, JB [1 ]
MILLS, AL [1 ]
COLWELL, RR [1 ]
机构
[1] UNIV MARYLAND,DEPT MICROBIOL,COLLEGE PK,MD 20742
关键词
D O I
10.1128/AEM.35.4.756-761.1978
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
引用
收藏
页码:756 / 761
页数:6
相关论文
共 50 条
  • [1] EVALUATION OF NUTRIENT AGARS FOR THE ENUMERATION OF VIABLE AEROBIC HETEROTROPHS IN COOLING WATER
    BROZEL, VS
    CLOETE, TE
    WATER RESEARCH, 1992, 26 (08) : 1111 - 1117
  • [2] ACCURACY AND PRECISION OF THE SPIRAL PLATE METHOD
    GERATS, GE
    SNIJDERS, JMA
    FLEISCHWIRTSCHAFT, 1979, 59 (02): : 256 - 258
  • [3] ENUMERATION OF HETEROTROPHS IN RIVER WATER WITH SPREAD PLATE METHOD: COMPARISON OF YEAST EXTRACT AGAR AND R2A AGAR
    Kapetanovic, Damir
    Dragun, Zrinka
    Valic, Damir
    Teskeredzic, Zlatica
    Teskeredzic, Emin
    FRESENIUS ENVIRONMENTAL BULLETIN, 2009, 18 (7B): : 1276 - 1280
  • [4] Evaluation of the Petrifilm plate method for the enumeration of aerobic microorganisms and coliforms in retailed meat samples
    Park, YH
    Seo, KS
    Ahn, JS
    Yoo, HS
    Kim, SP
    JOURNAL OF FOOD PROTECTION, 2001, 64 (11) : 1841 - 1843
  • [5] EVALUATION OF THE 3M PETRIFILM CULTURE PLATE METHOD FOR ENUMERATING AEROBIC FLORA AND COLIFORMS IN POULTRY-PROCESSING FACILITIES
    MCALLISTER, JS
    STADTHERR, MP
    FOX, TL
    JOURNAL OF FOOD PROTECTION, 1988, 51 (08) : 658 - &
  • [6] Comparison of the SimPlate™ total plate count method with Petrifilm™, Redigel™, and conventional pour-plate methods for enumerating aerobic microorganisms in foods
    Beuchat, LR
    Copeland, F
    Curiale, MS
    Danisavich, T
    Gangar, V
    King, BW
    Lawlis, TL
    Likin, RO
    Okwusoa, J
    Smith, CF
    Townsend, DE
    JOURNAL OF FOOD PROTECTION, 1998, 61 (01) : 14 - 18
  • [7] PRECISION AND ACCURACY - CONCEPTS AND ASSESSMENT BY METHOD EVALUATION TESTING
    WESTGARD, JO
    CRC CRITICAL REVIEWS IN CLINICAL LABORATORY SCIENCES, 1981, 13 (04): : 283 - 330
  • [8] CRITERIA FOR JUDGING PRECISION AND ACCURACY IN METHOD DEVELOPMENT AND EVALUATION
    WESTGARD, JO
    CAREY, RN
    WOLD, S
    CLINICAL CHEMISTRY, 1974, 20 (07) : 825 - 833
  • [9] Evaluation of the methods for enumerating coliform bacteria from water samples using precise reference standards
    Wohlsen, T
    Bates, J
    Vesey, G
    Robinson, WA
    Katouli, M
    LETTERS IN APPLIED MICROBIOLOGY, 2006, 42 (04) : 350 - 356
  • [10] DRINKING WATER HETEROTROPHIC PLATE COUNT: MONITORING METHOD PRECISION
    Zhao, Bingjie
    Randall, Andrew Amis
    Taylor, James S.
    FRESENIUS ENVIRONMENTAL BULLETIN, 2012, 21 (5A): : 1202 - 1211