INFLUENCE OF MASKER BANDWIDTH ON BINAURAL MASKING LEVEL DIFFERENCES

被引:0
|
作者
HARRIS, RW
BREY, RH
MILLER, RW
CHANNELL, RW
机构
[1] MAYO CLIN AUDIOL,ROCHESTER,MN
[2] ST JOHNS MED CTR,JOPLIN,MO
来源
AUDIOLOGY | 1992年 / 31卷 / 04期
关键词
MASKING LEVEL DIFFERENCE; CENTRAL AUDITORY TESTS;
D O I
暂无
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Masking level differences (MLDs) were investigated using masking noise with 160 Hz (amplitude-modulated noise) and 600 Hz (filtered-random noise) bandwidth. One hundred normally hearing subjects received the MLD test under both types of noise. Significant differences between noise types were observed in both N0S(pi) and N(pi)S0 conditions; MLDs were larger in amplitude-modulated noise. Consideration of these differences would indicate that older MLD norms based solely on filtered-random noise are invalid for amplitude-modulated noise especially where bandwidth differences in the noise exist. Were the norms for 600-Hz-wide filtered-random noise to be applied to results of MLD testing performed using 160-Hz-wide amplitude-modulated noise, patients with lesions in the central auditory pathway might exhibit normal or borderline normal results. Clinical MLD norms established on one type of noise should not be used to interpret MLD results obtained using a different type of noise.
引用
收藏
页码:196 / 204
页数:9
相关论文