A POLYMERIC LIQUID-CRYSTAL CAPILLARY COLUMN FOR GC-MS ANALYSIS OF PCDD AND PCDF

被引:0
|
作者
ALBRECHT, ID
NAIKWADI, KP
KARASEK, FW
机构
来源
关键词
GAS CHROMATOGRAPHY; POLYMERIC LIQUID CRYSTAL STATIONARY PHASE; POLYSILOXANE; PCDD; PCDF;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A newly developed side chain liquid crystal polysiloxane has been investigated as a stationary phase for the isomer-specific analysis of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans substituted at positions 2, 3, 7, and 8. The retention times from the chromatograms of a standard solution containing all PCDD and PCDF isomers were compared with those from solutions containing only those tetra- to octachlorinated compounds substituted at positions 2, 3, 7, and 8. In general, PCDDs substituted at positions 2, 3, 7, and 8 eluted later than most other isomers of the same congener group. The separations obtained on this stationary phase were compared with those obtained elsewhere using a commercially available product.
引用
收藏
页码:143 / 146
页数:4
相关论文
共 50 条
  • [1] Isomeric analysis of PCDD/PCDF in waste incinerator flyash by GC-MS/MS
    Cunliffe, AM
    Williams, PT
    [J]. CHEMOSPHERE, 2006, 62 (11) : 1846 - 1855
  • [2] ISOMER SPECIFIC ANALYSIS OF PCDD/F BY HRGC-MS USING POLYMERIC LIQUID-CRYSTAL STATIONARY PHASES
    ALBRECHT, ID
    NAIKWADI, KP
    KARASEK, FW
    [J]. CHEMOSPHERE, 1992, 25 (7-10) : 1271 - 1276
  • [3] IMPROVEMENTS IN GC MS STRATEGIES AND METHODOLOGIES FOR PCDD AND PCDF ANALYSIS .1. EVALUATION OF THE NONPOLAR DB-5MS COLUMN
    FRAISSE, D
    PAISSE, O
    HONG, LN
    GONNORD, MF
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (1-2): : 154 - 158
  • [4] Application of GC-MS/MS for the analysis of PCDD/Fs in sewage effluents
    Küchler, T
    Brzezinski, H
    [J]. CHEMOSPHERE, 2000, 40 (02) : 213 - 220
  • [5] APPLICATION OF A DIRECT GC-MS COUPLING TO A GLASS CAPILLARY COLUMN
    KOHLER, M
    HOHN, M
    [J]. CHROMATOGRAPHIA, 1976, 9 (12) : 611 - 617
  • [6] ANALYTICAL METHOD OF GUAZATINE BY GC-MS WITH A SHORT CAPILLARY COLUMN
    IMANAKA, M
    KADOTA, M
    OGAWA, N
    KUMASHIRO, K
    MORI, T
    [J]. JOURNAL OF PESTICIDE SCIENCE, 1993, 18 (02): : 141 - 146
  • [7] ISOMER SPECIFIC ANALYSIS OF CHLORINATED DIOXINS AND OTHER COMPOUNDS BY GC AND GC-MS USING POLYMERIC LIQUID CRYSTAL STATIONARY PHASES
    Albrecht, Iris D.
    Naikwadi, Krishnat P.
    Karasek, Francis W.
    Hatano, Hiroyuki
    [J]. ANALYTICAL SCIENCES, 1991, 7 : 215 - 218
  • [8] ANALYSIS OF ACIDIC METABOLITES BY CAPILLARY COLUMN GC AND GC/MS
    LIEBICH, HM
    [J]. JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1983, 6 (12): : 640 - 650
  • [9] PROSPECTIVES OF POLYMERIC LIQUID-CRYSTAL STATIONARY PHASES FOR CAPILLARY COLUMN GAS-CHROMATOGRAPHIC SEPARATIONS
    NAIKWADI, KP
    MCGOVERN, AM
    KARASEK, FW
    [J]. CANADIAN JOURNAL OF CHEMISTRY-REVUE CANADIENNE DE CHIMIE, 1987, 65 (05): : 970 - 975
  • [10] Rapid GC-MS analysis of methamphetamine and its metabolites in urine-application of a short narrow-bore capillary column to GC-MS
    Fujii, Hiroshi
    Hara, Kenji
    Kashimura, Seiichi
    Kageura, Mitsuyoshi
    Kashiwagi, Masayuki
    Miyoshi, Aya
    Ikeda, Sachiko
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 842 (02): : 116 - 120