The efficiency and safety of percutaneous closure of secundum atrial septal defects with the Occlutech Figulla device: Initial clinical experience

被引:0
|
作者
Ilkay, Erdogan [1 ]
Kacmaz, Fehmi [3 ]
Ozeke, Ozcan [1 ]
Turan, Rahsan Sarper [1 ]
Firat, Sakine [1 ]
Pampal, Kutluk [2 ]
Ozer, Esra [2 ]
Bilgin, Selcuk [2 ]
机构
[1] Mesa Hosp, Dept Cardiol, Ankara, Turkey
[2] Mesa Hosp, Dept Anesthesiol, Ankara, Turkey
[3] Tatvan Mil Hosp, Dept Cardiol, Bitlis, Turkey
关键词
Echocardiography; heart catheterization; heart septal defects; atrial/therapy; prosthesis design;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: We evaluated the efficiency and safety of the Occlutech Figulla device in percutaneous closure of secundum atrial septal defects (ASD). Study design: The study included 28 patients (17 women, 11 men; mean age 43 years) who underwent percutaneous transcatheter closure using the Occlutech Figulla device for secundum ASDs causing a hemodynamically significant shunt. Defect size was estimated by transthoracic (TTE) and transesophageal (TEE) echocardiography, and also by balloon sizing in nine patients. The patients were followed-up for six months and were examined by TTE. Results: The mean defect size was 20.3 +/- 2.1 mm on TTE, 22.1 +/- 1.9 mm on TEE, and 24.2 +/- 2.4 mm on balloon sizing. The mean device size was 26.8 +/- 3.6 mm (range 6 to 36 mm). The mean procedure time was 44.7 +/- 21.4 minutes. The device was placed successfully in all the patients. A small residual flow was seen immediately after device placement in three patients (10.7%), which disappeared in two patients at three months, and in one patient at six months. During the procedure, complications were seen in four patients (14.3%), including transient sinus tachycardia in three patients (10.7%) and acute atrial fibrillation in one patient (3.6%). At six months, all the patients were asymptomatic. No ischemic stroke, cardiac perforation, device erosion, embolization, thrombus formation, or malposition of the device were observed. Conclusion: The Occlutech Figulla occluder is a safe and efficient device to close secundum ASDs. It may be preferred especially in patients with a high risk for thrombus formation.
引用
收藏
页码:189 / 193
页数:5
相关论文
共 50 条
  • [1] EFFICIENCY AND SAFETY OF TRANSCATHETER CLOSURE OF SECUNDUM ATRIAL SEPTAL DEFECTS WITH THE OCCLUTECH FIGULLA SEPTAL OCCLUDER: INITIAL SINGLE CENTRE EXPERIENCE
    Oto, A.
    Aytemir, K.
    Canpolat, U.
    Ates, A. H.
    Yorgun, H.
    Sunman, H.
    Sahiner, L.
    Kaya, E. B.
    Tokgozoglu, L.
    Kabakci, G.
    Ozkutlu, S.
    Ozkutlu, H.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 : S141 - S141
  • [2] Successful closure of a very large secundum atrial septal defect with the Occlutech Figulla® device
    Tasal, Abdurrahman
    Bacaksiz, Ahmet
    Erdogan, Ercan
    Sonmez, Osman
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2012, 8 (04): : 347 - 350
  • [3] Early Results of Percutaneous Closure of the Atrial Septal Defects with Occlutech Figulla Devices: A Single Center Experience
    Kwon, Hye Won
    Lim, Hyo Bin
    Kim, Seong-Ho
    Lee, Sang Yun
    Jang, So Ick
    Park, Su-Jin
    Song, Mi Kyoung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (16) : S31 - S32
  • [4] Mid-Term Outcomes after Percutaneous Closure of the Secundum Atrial Septal Defect with the Figulla-Occlutech Device
    Pedra, Carlos A. C.
    Pedra, Simone F.
    Costa, Rodrigo N.
    Ribeiro, Marcelo S.
    Nascimento, Wanda
    Campanha, Luis Otavio S.
    Santana, M. Virginia T.
    Jatene, Ieda B.
    Assef, Jorge E.
    Fontes, Valmir F.
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2016, 29 (02) : 208 - 215
  • [5] Percutaneous closure of a postoperative residual atrial septal defect with the Occlutech Figulla Occluder device
    Demir, Bulent
    Tureli, Hande Oktay
    Kutlu, Gonul
    Karakaya, Osman
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2012, 40 (01): : 55 - 58
  • [6] Implantation of the Figulla Occlutech® device in a patient with an ostium secundum atrial septal defect
    Peruga, Jan
    Krecki, Radoslaw
    Chrzanowski, Lukasz
    Krzeminska-Pakula, Maria
    Kasprzak, Jarostaw D.
    KARDIOLOGIA POLSKA, 2008, 66 (06) : 658 - 660
  • [7] Percutaneous closure of multiple atrial septal defects in a child utilizing three Occlutech Figulla septal occluders: A bailout
    Bulbul, Ziad
    Hussein, Haytham Bou
    Sawaya, Fadi
    Bitar, Fadi
    ANNALS OF PEDIATRIC CARDIOLOGY, 2024, 17 (01) : 67 - 69
  • [8] Atrial tachyarrhythmias following percutaneous device closure of secundum atrial septal defects
    Vyas, Vishal
    Kaura, Amit
    Sawhney, Vinit
    Lowe, Martin
    Ezzat, Vivienne
    IJC HEART & VASCULATURE, 2020, 27
  • [9] Percutaneous closure of secundum atrial septal defects
    Albers, Erin
    Janssen, Dana
    Ammons, Drew
    Doyle, Thomas
    PROGRESS IN PEDIATRIC CARDIOLOGY, 2012, 33 (02) : 115 - 123
  • [10] Comparison of the Occlutech® Figulla® Septal Occluder and Amplatzer® Septal Occluder for Atrial Septal Defect Device Closure
    Supaporn Roymanee
    Worakan Promphan
    Nakharin Tonklang
    Kanjarut Wongwaitaweewong
    Pediatric Cardiology, 2015, 36 : 935 - 941