Specificity of Power Losses in Large Rectifier Transformers

被引:0
|
作者
Berlec, Maks [1 ]
Lenasi, Konrad [1 ]
机构
[1] Univ Ljubljani, Fak Elektrotehniko, Trzaska C 25, Ljubljana 1000, Slovenia
来源
关键词
rectifier transformer; method of images; eddy currents;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Additional power losses in large rectifier transformers are caused by induced eddy currents in their windings' conductors and other conductive parts of these transformers. When designing these transformers, the calculation of additional power losses inside windings shall be paid more attention than the calculation of those of the ordinary transformer. The currents in the windings are not sinusoidal and contain a large amount of harmonics, e.g. odd harmonics (Table 1). The most troublesome are the 180 degrees phase-shifted harmonics (5, 7, 17, 19...) for causing a lot of additional power losses inside region A (Fig. 5). As seen from Eq. 3, the magnetic field distribution inside the transformer window needs to be calculated. The method (Fig. 3) appropriate for this task is the method of images. It enables a direct, simple and fast calculation of the magnetic flux density. The basic idea of the method is to remove ferromagnetic objects from the space of calculation in order to apply Eqs. 1 and 2. In that case the magnetic field can be calculated by superposition of magnetic fields of transformer windings and their images.
引用
收藏
页码:75 / 78
页数:4
相关论文
共 50 条
  • [1] A COMPARISON OF INSTRUMENTATION FOR MEASURING THE LOSSES OF LARGE POWER TRANSFORMERS
    MALEWSKI, R
    ARSENEAU, R
    SO, E
    MOORE, WJM
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (06): : 1570 - 1573
  • [2] EDDY-CURRENT LOSSES IN RECTIFIER TRANSFORMERS
    CREPAZ, S
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (07): : 1651 - &
  • [3] INTERPHASE TRANSFORMERS IN POWER RECTIFIER CIRCUITS
    WELLS, R
    ELECTRICAL REVIEW, 1977, 200 (07): : 28 - 30
  • [4] POWER LOSSES OF FLYBACK TRANSFORMERS
    ZHENSHENG, Z
    ZUXUN, Y
    IEEE TRANSACTIONS ON CONSUMER ELECTRONICS, 1981, 27 (02) : 177 - 186
  • [5] ANALYSIS OF ELECTROMAGNETIC FIELDS AND EDDY CURRENT LOSSES IN LARGE POWER TRANSFORMERS
    Xia, Haixia
    Shen, Wanli
    Xu, Qiuyuan
    Gu, Weisi
    Yang, Shiyou
    MATERIAL ENGINEERING AND MECHANICAL ENGINEERING (MEME2015), 2016, : 1141 - 1152
  • [6] Errors and their reducing methods in digitized losses measurement of large power transformers
    Gaodianya Jishu/High Voltage Engineering, 1997, 23 (02): : 9 - 12
  • [7] STUDY ON EDDY-CURRENT LOSSES AND SHIELDING MEASURES IN LARGE POWER TRANSFORMERS
    CHEN, YB
    YANG, JY
    YU, HN
    TANG, RY
    IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (05) : 3068 - 3071
  • [8] Multipulse power rectifier without using multiphase transformers
    de Freitas, LCG
    Coelho, EAA
    Parreira, ÉF
    Oliveira, MAG
    de Freitas, LC
    IECON 2005: THIRTY-FIRST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, 2005, : 519 - 524
  • [9] Analytical power losses model of boost rectifier
    Ivanovic, Zeljko
    Blanusa, Branko
    Knezic, Mladen
    IET POWER ELECTRONICS, 2014, 7 (08) : 2093 - 2102
  • [10] Active and Reactive Power Losses in Distribution Transformers
    Kolcun, Michal
    Gawlak, Anna
    Kornatka, Miroslaw
    Conka, Zsolt
    ACTA POLYTECHNICA HUNGARICA, 2020, 17 (01) : 161 - 174