USE OF POLYTETRAFLUOROETHYLENE SURGICAL MEMBRANE AS A PERICARDIAL SUBSTITUTE

被引:0
|
作者
LOEBE, M
ALEXIMESKHISVILI, V
WENG, Y
HAUSDORF, G
HETZER, R
机构
关键词
HEART DEFECTS; CONGENITAL; SURGERY; MEMBRANES; ARTIFICIAL; PERICARDIUM; ADHESIONS; POLYTETRAFLUOROETHYLENE; THERAPEUTIC USE; REOPERATION;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Patients who undergo repair of congenital heart defects have a high probability of eventually needing a repeat operation. In such cases, use of a pericardial substitute can preclude adhesion formation, thereby helping to avert the complications of a repeat sternotomy. This report describes our use of the GORE-TEX(R) polytetrafluoroethylene surgical membrane in 321 patients who underwent repair of congenital heart disease at our hospital between May of 1989 and December of 1992 (these cases account for 37.1% of all such repairs performed during this period). The patients' ages ranged from 2 days to 31 years (mean, 5.9 years). Eighty-eight patients (27.4%) had at least 1 previous median sternotomy, and 234 (73.0%) had a moderate to high probability of reoperation. Seventy-eight patients (24.3%) received a homograft, which was positioned extracardially in 63 cases. During a maximum follow-up period of 43 months (mean, 26 +/- 5.6 months), 11 patients died, for an overall mortality of 3.4%. In no case was death attributable to membrane-related complications. Postoperative complications were encountered in 12 patients (3.7%), 1 0 of whom required an early repeat thoracotomy. One patient had mediastinitis, for an incidence of 0.3% (in contrast to 0.2% in 864 patients who underwent similar repair without the use of a surgical membrane). No complications were encountered in the 27 patients in whom the membrane was implanted during delayed sternal closure. Seventeen patients (5.5% of the survivors) underwent a repeat sternotomy, for further correction of congenital heart defects, a mean of 20 months after the original repair. At reoperation, no major complications were encountered. Although the number of reoperations was low, we conclude that use of the polytetrafluoroethylene surgical membrane for pericardial closure in children is a safe procedure that helps prevent complications at reoperation.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 50 条
  • [1] LONG-TERM RESULTS OF THE CLINICAL USE OF AN EXPANDED POLYTETRAFLUOROETHYLENE SURGICAL MEMBRANE AS A PERICARDIAL SUBSTITUTE
    HARADA, Y
    IMAI, Y
    KUROSAWA, H
    HOSHINO, S
    NAKANO, K
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1988, 96 (05): : 811 - 815
  • [2] USE OF EXPANDED POLYTETRAFLUOROETHYLENE PERICARDIAL SUBSTITUTE WITH VENTRICULAR ASSIST DEVICES
    HOLMAN, WL
    BOURGE, RC
    ZORN, GL
    BRANTLEY, LH
    KIRKLIN, JK
    ANNALS OF THORACIC SURGERY, 1993, 55 (01): : 181 - 183
  • [3] EXPANDED POLYTETRAFLUOROETHYLENE SURGICAL MEMBRANE FOR PERICARDIAL CLOSURE - AN EXPERIMENTAL-STUDY
    REVUELTA, JM
    GARCIARINALDI, R
    VAL, F
    CREGO, R
    DURAN, CMG
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1985, 89 (03): : 451 - 455
  • [4] Experience with the use of polytetrafluoroethylene pericardial membrane (preclude pericardial membrane) for retroperitoneal closure after abdominal aortic surgery
    Abad, C
    JOURNAL OF CARDIOVASCULAR SURGERY, 1997, 38 (03): : 283 - 286
  • [5] EXPERIENCE WITH THE POLYTETRAFLUOROETHYLENE SURGICAL MEMBRANE FOR PERICARDIAL CLOSURE IN OPERATIONS FOR CONGENITAL CARDIAC DEFECTS
    AMATO, JJ
    COTRONEO, JV
    GALDIERI, RJ
    ALBOLIRAS, E
    ANTILLON, J
    VOGEL, RL
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1989, 97 (06): : 929 - 934
  • [6] Surgical application of fascia lata as a pericardial substitute in rabbits
    Abedi, Gholamreza
    Shahzamani, Peyman
    Shahzamani, Mehran
    Mortazavi, Pejman
    Haghdost, Iraj Sohrabi
    Rafiei, Siyamak Mashhadi
    Ghods, Kamran
    ACTA CIRURGICA BRASILEIRA, 2012, 27 (08) : 557 - 560
  • [7] POLYTEF (POLYTETRAFLUOROETHYLENE) ALLOPLASTIC GRAFTING AS A SUBSTITUTE FOR MUCOUS-MEMBRANE
    LEVIN, PS
    DUTTON, JJ
    ARCHIVES OF OPHTHALMOLOGY, 1990, 108 (02) : 282 - 285
  • [8] A novel bioabsorbable pericardial membrane substitute to reduce postoperative pericardial adhesions in a rabbit model
    Chen, Zerui
    Zheng, Jilin
    Zhang, Jiajia
    Li, Shoujun
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 21 (05) : 565 - 572
  • [9] Decellularized Amniotic Membrane Scaffold as a Pericardial Substitute: An In Vivo Study
    Francisco, J. C.
    Correa Cunha, R.
    Cardoso, M. A.
    Baggio Simeoni, R.
    Mogharbel, B. F.
    Picharski, G. L.
    Silva Moreira Dziedzic, D.
    Guarita-Souza, L. C.
    Carvalho, K. A. T.
    TRANSPLANTATION PROCEEDINGS, 2016, 48 (08) : 2845 - 2849
  • [10] PERICARDIAL CLOSURE WITHOUT PERICARDIAL SUBSTITUTE
    BERRY, WR
    KLINGMAN, RR
    FERRARIS, VA
    ANNALS OF THORACIC SURGERY, 1993, 55 (06): : 1580 - 1581