POTENTIAL ERRORS DUE TO ALIASING IN DIGITAL VIDEO ANALYSIS OF QUANTITATIVE AUTORADIOGRAPHY

被引:4
|
作者
LAPIN, GD
GROOTHUIS, DR
机构
[1] NORTHWESTERN UNIV,EVANSTON HOSP,DEPT BIOMED ENGN,EVANSTON,IL 60201
[2] NORTHWESTERN UNIV,EVANSTON HOSP,INST NEUROSCI,EVANSTON,IL 60201
关键词
AUTORADIOGRAPHY; QUANTITATIVE AUTORADIOGRAPHY; DIGITAL IMAGING; DIGITAL VIDEO; ALIASING; SAMPLING; IMAGE ANALYSIS;
D O I
10.1016/0165-0270(91)90156-T
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Digital image analysis of quantitative autoradiographic (QAR) films is widely used in neuroscience applications. Unless proper precautions are taken when autoradiographic images are converted to digital form they can be inadvertently modified by improper application of the sampling process. This type of modification is termed aliasing error and can cause nonexistent structures to appear in the reconstructed digital image, changing the apparent optical density values of the data. The theoretical basis of aliasing error is presented, along with examples of aliasing from optical resolution test patterns and 2-deoxy[C-14]glucose (2-DG) experimental QAR images. We show that aliasing can change the apparent shape of structures, as well as the derived values obtained from QAR experiments. In an example with experimental 2-DG images, aliasing in the cerebellar cortex consistently underestimates tissue radioactivity levels in gray matter (P < 0.001) and overestimates levels in adjacent white matter (P < 0.001). Additional data transformations, such as the equations used for blood flow or glucose utilization, can, somewhat unpredictably, accentuate the errors introduced by aliasing. We present a discussion of the autoradiographic image features and electronics design that play a role in introducing aliasing errors and means by which aliasing can be recognized and minimized.
引用
收藏
页码:71 / 80
页数:10
相关论文
共 50 条
  • [1] MINIMIZING ALIASING ERRORS OF SENSORS WITH DIGITAL OUTPUT
    WOSCHNI, EG
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1987, 20 (02): : 119 - 124
  • [2] QUANTITATIVE DIGITAL AUTORADIOGRAPHY BY VIDEODENSITOMETRY
    YONEKURA, Y
    MEYER, M
    BRILL, AB
    SOM, P
    LEE, H
    RUSSELL, JAG
    BENNETT, GW
    JOURNAL OF NUCLEAR MEDICINE, 1981, 22 (06) : P14 - P14
  • [3] ANALYSIS OF POTENTIAL ERRORS IN QUANTITATIVE CHROMATOGRAPHY
    MAERSCHEL, RJ
    WELLBY, ML
    PATHOLOGY, 1974, 6 (02) : 204 - 204
  • [4] ALIASING ERRORS IN SIGNATURE ANALYSIS REGISTERS
    WILLIAMS, TW
    DAEHN, W
    GRUETZNER, M
    STARKE, CW
    IEEE DESIGN & TEST OF COMPUTERS, 1987, 4 (02): : 39 - 45
  • [5] USE OF DIGITAL RADIOGRAPHY SYSTEM FOR QUANTITATIVE DIGITAL AUTORADIOGRAPHY
    ALBRIGHT, RE
    SUDDARTH, SA
    FRAM, EK
    HARBURY, OL
    DRAYER, BP
    PUTMAN, CE
    INVESTIGATIVE RADIOLOGY, 1984, 19 (05) : S28 - S28
  • [6] Time aliasing errors in FIR filtered digital double integration
    Ribeiro, JGT
    de Castro, JTP
    Freire, JLD
    de Matos, MC
    PROCEEDINGS OF THE SEM IX INTERNATIONAL CONGRESS ON EXPERIMENTAL MECHANICS, 2000, : 171 - 174
  • [7] ALIASING ERRORS IN SHORT-TIME ANALYSIS
    YARLAGADDA, R
    ALLEN, JB
    SIGNAL PROCESSING, 1982, 4 (01) : 79 - 84
  • [8] DIGITAL SIGNAL ANALYSIS AND ALIASING.
    Enochson, Loren
    S V Sound and Vibration, 1987, 21 (03): : 28 - 31
  • [9] Quantitative photogrammetric analysis of digital underwater video imagery
    Li, RX
    Li, HH
    Zou, WH
    Smith, RG
    Curran, TA
    IEEE JOURNAL OF OCEANIC ENGINEERING, 1997, 22 (02) : 364 - 375
  • [10] QUANTITATIVE DIGITAL SUBTRACTION AUTORADIOGRAPHY OF BRAIN OPIOID RECEPTORS
    SHARIF, NA
    CLARK, CR
    BROWN, TOM
    HUGHES, J
    BIOCHEMICAL SOCIETY TRANSACTIONS, 1986, 14 (04) : 688 - 690