MEASUREMENT OF TIDAL LUNG-VOLUMES IN NEONATES DURING HIGH-FREQUENCY OSCILLATION

被引:13
|
作者
HOSKYNS, EW [1 ]
MILNER, AD [1 ]
HOPKIN, IE [1 ]
机构
[1] CITY HOSP NOTTINGHAM,DEPT NEONATAL MED & SURG,HUCKNALL RD,NOTTINGHAM NG5 1PD,ENGLAND
来源
JOURNAL OF BIOMEDICAL ENGINEERING | 1992年 / 14卷 / 01期
关键词
HIGH FREQUENCY OSCILLATION; TIDAL VOLUME; RESPIRATORY DISTRESS SYNDROME; RESPIRATORY JACKET;
D O I
10.1016/0141-5425(92)90030-O
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High-frequency oscillation (HFO) has been used clinically to ventilate infants with respiratory distress. However, there are problems in monitoring the effects on the respiratory system and in particular in measuring the volumes delivered; this is important information in terms of safety and mechanisms of action of HFO. We have validated two sizes of respiratory jacket for measuring oscillatory volume changes of 0.25-5 ml at frequencies of 2-25 Hz, the volume delivered from a purpose-built oscillator having first been validated. Different combinations of volume and frequencies were then oscillated into each jacket, while it was being worn by a well preterm baby. Studies were performed with each jacket on five babies with weights between 0.82 and 1.86 kg. The results showed that at any given frequency there was a linear relationship between the pressure oscillations measured from a side port of the jacket and the delivered volume. Both jackets showed the same pattern of frequency response, overreading at < 10 Hz and underreading at 10-25 Hz. When appropriately calibrated, the respiratory jacket can be used as a non-invasive method of measuring volumes delivered by HFO.
引用
收藏
页码:16 / 20
页数:5
相关论文
共 50 条
  • [1] ALVEOLAR PRESSURES AND LUNG-VOLUMES DURING HIGH-FREQUENCY OSCILLATORY VENTILATION IN DOGS
    ARMENGOL, J
    JONES, RL
    KING, EG
    [J]. CRITICAL CARE MEDICINE, 1985, 13 (08) : 632 - 636
  • [2] MEASUREMENT OF TIDAL VOLUME USING A PNEUMOTACHOMETER DURING HIGH-FREQUENCY OSCILLATION
    COURTNEY, SE
    SPOHN, WA
    WEBER, KR
    MALIN, SW
    BENDER, CV
    GOTSHALL, RW
    [J]. CLINICAL RESEARCH, 1988, 36 (06): : A905 - A905
  • [3] MEASUREMENT OF TIDAL VOLUME USING A PNEUMOTACHOMETER DURING HIGH-FREQUENCY OSCILLATION
    COURTNEY, SE
    WEBER, KR
    SPOHN, WA
    MALIN, SW
    BENDER, CV
    GOTSHALL, RW
    [J]. CRITICAL CARE MEDICINE, 1990, 18 (06) : 651 - 653
  • [4] DYNAMIC LUNG-INFLATION DURING HIGH-FREQUENCY OSCILLATION IN NEONATES
    HOSKYNS, EW
    MILNER, AD
    HOPKIN, IE
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 1992, 151 (11) : 846 - 850
  • [5] Measurement of tidal volumes in case of high frequency oscillation ventilation
    Wurm, M.
    Drauschke, A.
    Mader, J.
    Stiglbrunner, K.
    Weingant, M.
    Bawitsch, J.
    Kroesl, P.
    [J]. 4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 2057 - 2060
  • [6] LUNG-VOLUMES IN NEONATES AND INFANTS
    GAULTIER, C
    [J]. EUROPEAN RESPIRATORY JOURNAL, 1989, 2 : S130 - S134
  • [7] THE EFFECTS OF HIGH-FREQUENCY OSCILLATORY VENTILATION ON RESTING LUNG-VOLUMES IN DOGS
    ARMENGOL, J
    JONES, RL
    KING, EG
    [J]. CLINICAL RESEARCH, 1983, 31 (02): : A414 - A414
  • [8] MEASUREMENT OF LUNG-VOLUMES
    RIES, AL
    [J]. CLINICS IN CHEST MEDICINE, 1989, 10 (02) : 177 - 186
  • [9] VOLUME RECRUITMENT MANEUVERS ARE LESS DELETERIOUS THAN PERSISTENT LOW LUNG-VOLUMES IN THE ATELECTASIS-PRONE RABBIT LUNG DURING HIGH-FREQUENCY OSCILLATION
    BOND, DM
    FROESE, AB
    [J]. CRITICAL CARE MEDICINE, 1993, 21 (03) : 402 - 412
  • [10] Determinants of tidal volume during high-frequency oscillation
    Sedeek, KA
    Takeuchi, M
    Suchodolski, K
    Kacmarek, RM
    [J]. CRITICAL CARE MEDICINE, 2003, 31 (01) : 227 - 231