Five years have passed since the HI-13 tandem accelerator at CIAE was accepted from HVEC in 1986. In this period, one year consisted of testing operations and four years of full operation. The highest terminal voltage reached with the ion beam was 12.6 MV using the original 72 in. inclined field tubes. The laddertron chain has accumulated about 16000 h of running time up to now. Experimental beam time is about 14600 h. More than 20 ion species have been accelerated through the machine. In this paper, the operation, maintenance and improvement of the HI-13 tandem are described.
引用
收藏
页码:34 / 38
页数:5
相关论文
共 50 条
  • [1] The ten years' operation of the HI-13 tandem accelerator at CIAE
    Yang, BF
    Qin, JC
    Zhang, CZ
    Hu, YM
    Guan, XL
    Jiang, YL
    Zhang, GL
    Yang, WM
    Kan, CX
    Yang, ZR
    Su, SY
    Liu, DZ
    Wang, LY
    Zhu, JZ
    HEAVY ION ACCELERATOR TECHNOLOGY, 1999, 473 : 80 - 87
  • [2] Progresses in the project of upgrading HI-13 tandem accelerator at CIAE
    Yang, Bingfan
    Guan, Xialing
    Cao, Xiaoping
    Zhang, Tianjue
    Li, Zhenguo
    Chu, Chengjie
    Cui, Baoqun
    Zhou, Lipeng
    Peng, Zhaohua
    Bao, Yiwen
    Tang, Hongqing
    Wu, Haicheng
    He Jishu/Nuclear Techniques, 2008, 31 (01): : 41 - 46
  • [3] Twenty years of Beijing HI-13 tandem accelerator
    China Institute of Atomic Energy, P. O. Box 275-62, Beijing 102413, China
    Yuanzineng Kexue Jishu, 2009, SUPPL. 1 (147-149):
  • [4] THE IAE PEKING HI-13 TANDEM ACCELERATOR
    JUXIAN, Y
    NUCLEAR INSTRUMENTS & METHODS, 1981, 184 (01): : 157 - 159
  • [5] PROGRESS REPORT ON THE HI-13 TANDEM ACCELERATOR
    TIAN, YM
    YU, JX
    LIU, ZY
    YANG, SC
    QIN, JC
    GUAN, XL
    DU, XR
    NING, SL
    YANG, BF
    YU, YF
    WANG, JD
    HAN, RJ
    YANG, WM
    BI, DC
    ZHENG, ZY
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 244 (1-2): : 39 - 47
  • [6] TESTING AND COMMISSIONING OF THE HI-13 TANDEM ACCELERATOR
    QIN, JC
    YU, JX
    YANG, SC
    DU, XR
    LIU, ZY
    WANG, HP
    CHEN, WK
    HU, YM
    ZHANG, GL
    YANG, BF
    YU, YF
    GUAN, XL
    NING, SL
    YANG, WM
    GE, JY
    BI, DC
    ZHENG, ZY
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 268 (2-3): : 316 - 318
  • [7] Practice and innovation in the operation and maintenance of HI-13 tandem accelerator for 35 years
    Li K.
    Kan C.
    Wang X.
    Hu Y.
    Yang B.
    Qin J.
    Guan X.
    Su S.
    Bao Y.
    You Q.
    Wang H.
    Zhou J.
    Fan Q.
    Liu D.
    Yang T.
    Hu R.
    Yang B.
    He Jishu/Nuclear Techniques, 2023, 46 (08):
  • [8] Recent status of Beijing HI-13 tandem accelerator
    Hu, Yue-Ming
    Kan, Chao-Xin
    Bao, Yi-Wen
    Su, Sheng-Yong
    You, Qu-Bo
    Wang, Xiao-Fei
    Yang, Tao
    Fan, Hong-Sheng
    Fang, Yu-Qing
    Liu, De-Zhong
    Guan, Xia-Ling
    Yang, Bao-Jun
    Xia, Qing-Liang
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2008, 42 (SUPPL.): : 251 - 253
  • [9] HI-13 tandem accelerator radioactivity protection interlock system
    Li Ming-Long
    Wang Xiao-Fei
    Hu Ren-Wei
    CHINESE PHYSICS C, 2008, 32 : 93 - 95
  • [10] Upgrading the injector system of Beijing HI-13 tandem accelerator
    Bao, Yiwen
    Guan, Xialing
    Hu, Yueming
    Su, Shengyong
    You, Qubo
    Huang, Qinghua
    Wang, Xiaofei
    Kan, Chaoxin
    Yang, Tao
    Fan, Hongsheng
    Yang, Baojun
    Liu, Dezhong
    Yang, Bingfan
    Jiang, Shan
    He, Ming
    Liu, Weiping
    Hu, Renwei
    Ren, Yin
    Ma, Zhengyu
    Zhang, Xiuhua
    Yan, Fang
    Wang, Qiuju
    Li, Minglong
    He Jishu/Nuclear Techniques, 2007, 30 (12): : 1001 - 1002