TRANSMISSION OF CORNEAL COLLAGEN DURING ARF EXCIMER LASER ABLATION

被引:23
|
作者
EDIGER, MN [1 ]
PETTIT, GH [1 ]
WEIBLINGER, RP [1 ]
CHEN, CH [1 ]
机构
[1] JOHNS HOPKINS UNIV,SCH MED,WILMER OPHTHALMOL INST,BALTIMORE,MD 21205
关键词
PHOTOABLATION; PHOTOREFRACTIVE KERATOPLASTY; ULTRAVIOLET;
D O I
10.1002/lsm.1900130208
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
The time-resolved transmission of collagen films and 10-mum sections of bovine cornea during ArF laser ablation has been investigated. The film studies were performed on thin layers of extracted bovine corneal collagen, the principal chromophore in 193 nm photoablation. Transmission measurements were made on both dry and water-saturated films to assess the sensitivity of the ablation process to hydration. Distinct transient optical changes were observed in both fully desiccated and rehydrated films. Dehydrated films exhibit rapid reduction in film absorption over the time-course of the ablating laser pulse, presumably due to chromophore bleaching or annihilation. In contrast, rehydrated films demonstrate a short-lived enhancement of the attenuation. In either case, a single ablative laser pulse increased the long-term transmission of the film, although this increase was a factor of five greater for dehydrated films than for rehydrated samples. Results obtained from corneal tissue sections were essentially identical to those derived from hydrated collagen films.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 50 条
  • [1] Dynamic optical properties of collagen-based tissue during ArF excimer laser ablation
    Pettit, G.H.
    Ediger, M.N.
    Weiblinger, R.P.
    [J]. Applied Optics, 1993, 32 (04): : 488 - 493
  • [2] DYNAMIC OPTICAL-PROPERTIES OF COLLAGEN-BASED TISSUE DURING ARF EXCIMER LASER ABLATION
    PETTIT, GH
    EDIGER, MN
    WEIBLINGER, RP
    [J]. APPLIED OPTICS, 1993, 32 (04) : 488 - 493
  • [3] Human corneal ablation threshold using the 193-nm ArF excimer laser
    Berns, MW
    Chao, L
    Giebel, AW
    Liaw, LH
    Andrews, J
    VerSteeg, B
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (05) : 826 - 830
  • [4] PUMP-PROBE TRANSMISSION MEASUREMENTS OF CORNEAL TISSUE DURING EXCIMER-LASER ABLATION
    PETTIT, GH
    EDIGER, MN
    [J]. LASERS IN SURGERY AND MEDICINE, 1993, 13 (03) : 363 - 367
  • [5] STRUCTURING OF POLYIMIDE BY ARF EXCIMER LASER ABLATION
    SPIESS, W
    STRACK, H
    [J]. SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 1989, 4 (06) : 486 - 490
  • [6] EXCIMER LASER ABLATION OF A CORNEAL PROTUBERANCE
    BRANCATO, R
    SCIALDONE, A
    CARONES, F
    BERTUZZI, A
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (01): : 111 - 112
  • [7] OPTICAL-PROPERTIES OF POLYIMIDE DURING ARF EXCIMER-LASER ABLATION
    HAHN, DW
    PETTIT, GH
    EDIGER, MN
    [J]. JOURNAL OF APPLIED PHYSICS, 1994, 76 (03) : 1830 - 1832
  • [8] Excimer Ablation of Collagen-Based Corneal Substitutes
    Odorcic, Silvia
    Noel, Christopher
    Mitra, Debbie
    Priest, David
    Taylor, Sabrina
    Griffith, May
    Munger, Rejean
    Jackson, W. Bruce
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [9] DYNAMICS OF ABLATION PLUME PARTICLES GENERATED DURING EXCIMER-LASER CORNEAL ABLATION
    HAHN, DW
    EDIGER, MN
    PETTIT, GH
    [J]. LASERS IN SURGERY AND MEDICINE, 1995, 16 (04) : 384 - 389
  • [10] Thermal Load During Corneal Excimer Laser Ablation Impact of Different Ablation Parameters
    Taneri, Suphi
    Arba-Mosquera, Samuel
    Rost, Anika
    Dick, H. Burkhard
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (10) : 667 - +