Radio Frequency Modeling of Receive Coil Arrays for Magnetic Resonance Imaging

被引:10
|
作者
Stumpf, Christopher [1 ,3 ]
Malzacher, Matthias [2 ]
Schmidt, Lorenz-Peter [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nuremberg, Inst Microwaves & Photon, D-91058 Erlangen, Germany
[2] Heidelberg Univ, Med Fac Mannheim, Comp Assisted Clin Med, D-68167 Mannheim, Germany
[3] WORK Microwave, D-83607 Holzkirchen, Germany
关键词
receive coil array; SNR modeling; MRI; pre-amplifier noise; noise coupling;
D O I
10.3390/jimaging4050067
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
The numerical calculation of the signal-to-noise ratio (SNR) of magnetic resonance imaging (MRI) coil arrays is a powerful tool in the development of new coil arrays. The proposed method describes a complete model that allows the calculation of the absolute SNR values of arbitrary coil arrays, including receiver chain components. A new method for the SNR calculation of radio frequency receive coil arrays for MRI is presented, making use of their magnetic B-1 transmit pattern and the S-parameters of the network. The S-parameters and B-1(-) fields are extracted from an electromagnetic field solver and are post-processed using our developed model to provide absolute SNR values. The model includes a theory for describing the noise of all components in the receiver chain and the noise figure of a pre-amplifier by a simple passive two-port network. To validate the model, two-and four-element receive coil arrays are investigated. The SNR of the examined arrays is calculated and compared to measurement results using imaging of a saline water phantom in a 3 T scanner. The predicted values of the model are in good agreement with the measured values. The proposed method can be used to predict the absolute SNR for any receive coil array by calculating the transmit B-1(-) pattern and the S-parameters of the network. Knowledge of the components of the receiver chain including pre-amplifiers leads to satisfactory results compared to measured values, which proves the method to be a useful tool in the development process of MRI receive coil arrays.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Opencage radio frequency coil for magnetic resonance imaging
    Nikulin, A.
    de Rosny, J.
    Haliot, K.
    Larrat, B.
    Ourir, A.
    [J]. APPLIED PHYSICS LETTERS, 2019, 114 (05)
  • [2] Receive coil arrays and parallel imaging for functional magnetic resonance imaging of the human brain
    de Zwart, Jacco A.
    van Gelderen, Peter
    Duyn, Jeff H.
    [J]. 2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 6318 - +
  • [3] Automatic Resonance Frequency Retuning of Stretchable Liquid Metal Receive Coil for Magnetic Resonance Imaging
    Mehmann, Andreas
    Vogt, Christian
    Varga, Matija
    Port, Andreas
    Reber, Jonas
    Marjanovic, Josip
    Pruessmann, Klaas Paul
    Sporrer, Benjamin
    Huang, Qiuting
    Troster, Gerhard
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (06) : 1420 - 1426
  • [4] Perspectives in Wireless Radio Frequency Coil Development for Magnetic Resonance Imaging
    Nohava, Lena
    Ginefri, Jean-Christophe
    Willoquet, Georges
    Laistler, Elmar
    Frass-Kriegl, Roberta
    [J]. FRONTIERS IN PHYSICS, 2020, 8
  • [5] A novel radio frequency coil for veterinary magnetic resonance imaging system
    Meng Bin
    Huang Kai-Wen
    Wang Wei-Min
    [J]. CHINESE PHYSICS B, 2010, 19 (07)
  • [6] A novel radio frequency coil for veterinary magnetic resonance imaging system
    孟斌
    黄开文
    王为民
    [J]. Chinese Physics B, 2010, 19 (07) : 412 - 417
  • [7] A Radio-Frequency Neck Quadrature Coil for Magnetic-Resonance Imaging
    A. A. Bayazitov
    P. I. Chumarov
    Ya. V. Fattakhov
    [J]. Instruments and Experimental Techniques, 2018, 61 : 590 - 595
  • [8] A Radio-Frequency Neck Quadrature Coil for Magnetic-Resonance Imaging
    Bayazitov, A. A.
    Chumarov, P. I.
    Fattakhov, Ya. V.
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2018, 61 (04) : 590 - 595
  • [9] A fast integral equation method for simulating high-field radio frequency coil arrays in magnetic resonance imaging
    Wang, Shumin
    de Zwart, Jacco A.
    Duyn, Jeff H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (09): : 2779 - 2789
  • [10] MEMS switch integrated radio frequency coils and arrays for magnetic resonance imaging
    Bulumulla, S. B.
    Park, K. J.
    Fiveland, E.
    Iannotti, J.
    Robb, F.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):