3-DIMENSIONAL DISPLAY OF CARDIAC STRUCTURES USING RECONSTRUCTED MAGNETIC-RESONANCE-IMAGING

被引:6
|
作者
HOSONO, M
NAKANO, Y
URAYAMA, S
KONISHI, J
UOKAWA, K
TANAKA, Y
机构
[1] KANSAI MED SCH,DEPT RADIOL,OSAKA,JAPAN
[2] NATL CARDIOVASC CTR,RES INST,DEPT INVESTIGAT RADIOL,OSAKA,JAPAN
关键词
3-DIMENSIONAL DISPLAY; MR IMAGING; COMPUTER GRAPHICS;
D O I
10.1007/BF03168084
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
It is sometimes difficult to understand the three dimensional (3D) relationship of cardiac and mediastinal structures despite advances in magnetic resonance (MR) imaging techniques, We present a low-cost system for 3D reconstruction of the major mediastinal structures by processing the MR imaging data on a NeXT workstation. MR images of multisection, multiphase, spin-echo techniques stored in a picture archiving and communication system (PACS) data base were used for the reconstruction. The computer program obtained the contours of the multiple components of the mediastinal structures by the combination of automatic and manual procedure. The bundled software of a 3D kit was used for surface rendering of hidden surface removal, shading of the visible parts of the surfaces, perspective transformation, and motion parallax by rotation of the surfaces. 3D reconstruction was performed in 15 patients with cardiac diseases, and the 3D-reconstructed images were compared with the plain chest x rays of the patients. The 3D presentation dearly showed the complex anatomy of cardiovascular diseases and helped elucidate the misconceptions in the interpretation of the plain chest x rays. Our 3D images are used for education and should be viewed by medical students and beginners in radiology at an individual pace with plain chest radiographs, MR images, and legends. Although applied to the heart and the great vessels in this report, this system is also applicable to other structures. (C) 1995 by W.B. Saunders Company
引用
收藏
页码:105 / 115
页数:11
相关论文
共 50 条
  • [1] 3-DIMENSIONAL DISPLAY OF AIRWAY COMPRESSION BY VASCULAR STRUCTURES USING MAGNETIC-RESONANCE-IMAGING
    BAFFA, JM
    HOFFMAN, EA
    AXEL, L
    FELLOWS, KE
    WEINBERG, PM
    CIRCULATION, 1990, 82 (04) : 154 - 154
  • [2] FAST 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING
    IRARRAZABAL, P
    NISHIMURA, DG
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 656 - 662
  • [3] 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING OF A LIQUID FOAM
    PRAUSE, BA
    GLAZIER, JA
    GRAVINA, SJ
    MONTEMAGNO, CD
    JOURNAL OF PHYSICS-CONDENSED MATTER, 1995, 7 (40) : L511 - L516
  • [4] 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING - DISPLAY AND QUANTITATION OF EFFECTS OF ACUTE MYOCARDIAL-ISCHEMIA
    AURIGEMMA, G
    REICHEK, N
    TRIVEDI, S
    VENUGOPAL, R
    KUNDEL, H
    JOSEPH, P
    HERMAN, G
    CLINICAL RESEARCH, 1987, 35 (03): : A259 - A259
  • [5] 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING OF THE TEMPOROMANDIBULAR-JOINT
    WILK, RM
    HARMS, SE
    JOURNAL OF DENTAL RESEARCH, 1986, 65 : 287 - 287
  • [6] 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING IN SKULL BASE LESIONS
    GREVERS, G
    ASSAL, J
    VOGL, T
    WILIMZIG, C
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 1991, 12 (03) : 139 - 145
  • [7] 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING EVALUATION OF PEDIATRIC TRACHEOBRONCHIAL TREE
    DONNELLY, KJ
    BANK, ER
    PARKS, J
    GUSSACK, GS
    DAVENPORT, P
    TODD, NW
    SHEPHERD, S
    LARYNGOSCOPE, 1994, 104 (12): : 1425 - 1430
  • [8] 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING OF THE PROLACTIN-SECRETIN MICROADENOMAS
    GIRARD, N
    CORTESI, L
    CHABERTORSINI, V
    MAMAN, P
    BRUE, T
    JAQUET, P
    RAYBAUD, C
    ANNALES D ENDOCRINOLOGIE, 1992, 53 (01) : 8 - 15
  • [9] AUTOMATIC MAGNETIC-RESONANCE TISSUE CHARACTERIZATION FOR 3-DIMENSIONAL MAGNETIC-RESONANCE-IMAGING OF THE BRAIN
    PHILLIPS, WE
    VELTHUIZEN, RP
    PHUPHANICH, S
    SILBIGER, ML
    JOURNAL OF NEUROIMAGING, 1995, 5 (03) : 171 - 177
  • [10] 3-DIMENSIONAL DISPLAY FROM CROSS-SECTIONAL TOMOGRAPHIC-IMAGES - AN APPLICATION TO MAGNETIC-RESONANCE-IMAGING
    KENNEDY, DN
    NELSON, AC
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (02) : 134 - 140