EVALUATION OF TYPES OF PRE-ANALYTICAL ERRORS IN CLINICAL CHEMISTRY LABORATORY

被引:1
|
作者
Barapatre, Amit Ramesh [1 ]
Jadhao, Avinash Namdeo [1 ]
Lokhande, Manoj Chandrakant [1 ]
机构
[1] TNMC Nair & BYL Ch Hosp, Dept Biochem, Room 415,Fourth Floor,Coll Bldg, Mumbai Cent 08, Maharashtra, India
关键词
Pre-analytical Errors; Hemolysis; Lipemia;
D O I
10.14260/jemds/2016/1076
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE Evaluation of leading causes of pre-analytical errors in Clinical Biochemistry Laboratory. MATERIALS AND METHODS Samples were obtained from the OPD and indoor admitted patients and analysis of the results obtained from clinical chemistry laboratory obtained during one year of study period was done retrospectively. Data was summarised regarding the frequency of factors affecting the pre-analytical quality of results. Laboratory personnel were asked to register all the rejected samples and reasons for rejections. RESULTS Out of 62541 inpatient samples collected and screened over period, pre-analytical errors were observed in 4611 samples, which is approximately 3.75% of the total blood samples received. Insufficient volume of samples accounted for rejection of 2428 samples, which is 1.9% of total samples received during this period. Haemolysis accounted for rejection of 1.1% of samples and gross lipaemia was responsible for rejection of 0.4% samples. 0.26% of samples were rejected for having wrong/incomplete patient information. Out of 60244 samples collected total from OPD, 5552 samples were rejected for the presence of pre-analytical errors. This accounted for rejection of 4.5% of total samples received during this period. 2.7% of samples were rejected for the presence of visible haemolysis after centrifugation. Samples rejected for insufficient volume accounted to 1.9%. 0.3% of samples were rejected for having gross lipaemia. 800 samples were rejected for having wrong/incomplete patient information, which accounted for rejection of 0.8%. CONCLUSION The overall rate of rejection of samples is 8.52%, which is very high. Haemolysis was major reason for rejection of samples collected from OPD and error due to insufficient sample volume was found to be equal in both type of samples collected from OPD and indoor patients.
引用
收藏
页码:4722 / 4725
页数:4
相关论文
共 50 条
  • [1] FREQUENCY OF PRE-ANALYTICAL PHASE ERRORS IN A CLINICAL CHEMISTRY LABORATORY
    Zubair, Muhammad
    Raza, Ahmed
    Mahmood, Tahir
    [J]. INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 6 (05): : 8906 - 8909
  • [2] Frequency and types of pre-analytical errors in a clinical laboratory of a specialized healthcare hospital
    Tasneem, Aroofa
    Zubair, Muhammad
    Rasool, Zoha
    Tareen, Farrukh Zia
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2024, 40 (02) : S70 - S74
  • [3] Types and Frequencies of Pre-Analytical Errors in the Clinical Laboratory at the University Hospital of Korea
    Lee, N. Y.
    [J]. CLINICAL LABORATORY, 2019, 65 (09) : 1735 - 1743
  • [4] EVALUATION OF LABORATORY PERFORMANCE IN PROFICIENCY TESTING PROGRAMS FOR IDENTIFICATION OF PRE-ANALYTICAL ERRORS IN CHEMISTRY
    Wafula, B.
    Amayo, A.
    Chege, P.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S665 - S665
  • [5] Pre-analytical errors in the clinical laboratory: A risk assessment analysis
    Sengupta, S.
    Handoo, A.
    [J]. CLINICA CHIMICA ACTA, 2019, 493 : S502 - S502
  • [6] Clinical audit:: a tool to monitor pre-analytical errors in the laboratory
    Etcheverry, Graciela Susana
    Dominguez, Maria Virginia
    Esposito, Natalia
    Mayon, Paula Cecilia
    Jesus Morales, Martin
    Soledad Roselli, Maria
    Andrieu, Karina
    [J]. ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2007, 41 (01): : 51 - 56
  • [7] Evaluation of pre-analytical nonconformities in the laboratory of clinical pharmacology
    Ben Salem, F.
    Gaies, E.
    Salouage, I.
    Charfi, R.
    Jebabli, N.
    Ben Sassi, M.
    El Jebari, H.
    Klouz, A.
    Daghfous, R.
    Trabelsi, S.
    [J]. FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2018, 32 : 69 - 69
  • [8] TYPES AND FREQUENCIES OF PRE-ANALYTICAL SAMPLE ERRORS IN SPAIN
    Salinas, M.
    Lopez-Garrigos, M.
    Aguado, C.
    Carratala, A.
    Chinchilla, V.
    Diaz, J.
    Ortuno, M.
    Yago, M.
    Lorente, M. A.
    Uris, J.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S727 - S727
  • [9] TYPES AND FREQUENCIES OF PRE-ANALYTICAL SAMPLE ERRORS IN SPAIN
    Salinas, M.
    Lopez-Garrigos, M.
    Aguado, C.
    Carratala, A.
    Chinchilla, V.
    Diaz, J.
    Ortuno, M.
    Yago, M.
    Lorente, M. A.
    Uris, J.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S728 - S728
  • [10] PRE-ANALYTICAL WORKSTATIONS AS A TOOL FOR REDUCING LABORATORY ERRORS
    Da Rin, Giorgio
    [J]. JOURNAL OF MEDICAL BIOCHEMISTRY, 2010, 29 (04) : 315 - 324