INVIVO AND INVITRO STUDY OF THE LESIONS PRODUCED WITH A COMPUTERIZED RADIOFREQUENCY SYSTEM

被引:30
|
作者
VINAS, FC
ZAMORANO, L
DUJOVNY, M
ZHAO, JZ
HODGKINSON, D
HO, KL
AUSMAN, JI
机构
[1] HENRY FORD NEUROSURG INST,DETROIT,MI
[2] WAYNE STATE UNIV,CTR HLTH,DEPT NEUROSURG,DETROIT,MI 48201
关键词
STEREOTAXIC SURGERY; RADIOFREQUENCY; FUNCTIONAL NEUROSURGERY; LESION; ELECTRODES;
D O I
10.1159/000098985
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
For many years, radiofrequency-generated lesions have been used for the treatment of pain and abnormal movements. However, the reliability of this method has been questioned because of the variation in the size of lesions produced by the electrode at different times and temperatures. A 500-kHz radiofrequency generator with different electrodes was used to determine the size of lesions, using different time and temperature exposures. A computerized feedback mechanism kept the tip temperature constant during the production of the lesion, regardless of varying tissue impedance. Eight electrodes of different size and tip characteristics were evaluated at different temperatures and time settings, both in vitro and in vivo. Graphic display of the curves in time were obtained at 65, 70, 75, 80, 85 and 90-degrees-C. The effects of thermocoagulation were studied in vitro in fresh egg whites, using time intervals of 20, 40, 60, 80 and 100 s, and in vivo, in the subcortical white matter of 20 adult New Zealand white rabbits. Animals were sacrificed after 7 days. Lesions were photographed and measured under magnification. In all cases, the coagulated masses were ellipsoid, with regular, well-demarcated borders. A two-way statistical analysis of variance was done. The coagulum size increased with higher temperatures and with larger probes. The increase was significant in both diameter and length (p = 0.001). In contrast, the use of different times at the same level of temperature showed no significant increase in most of the electrodes. There were two statistical significant time effects, for both diameter and length, with the monopolar 2-mm electrode. The use of real-time monitoring with graphic display and the feedback information provided for the computerized control of power and current allows high precision of the temperature at the electrode tip during the production of the lesion.
引用
收藏
页码:121 / 133
页数:13
相关论文
共 50 条
  • [1] ULTRASTRUCTURAL STUDY OF PEMPHIGUS LESIONS PRODUCED INVITRO
    BARNETT, ML
    SUN, S
    BINDER, W
    BEUTNER, EH
    JOURNAL OF DENTAL RESEARCH, 1976, 55 : B111 - B111
  • [2] Lesions produced by radiofrequency ablation in a child
    Kantoch, M
    McKay, R
    CARDIOLOGY IN THE YOUNG, 1998, 8 (04) : 532 - 533
  • [3] LOCALIZATION OF STEREOTACTIC RADIOFREQUENCY THALAMIC LESIONS BY COMPUTERIZED AXIAL TOMOGRAPHY
    CALA, LA
    MASTAGLIA, FL
    VAUGHAN, RJ
    LANCET, 1976, 2 (7995): : 1133 - 1134
  • [4] INVITRO DETECTION OF LYMPHOKINES PRODUCED BY INVIVO ACTIVATED LYMPHOCYTES
    MOHLER, KM
    BUTLER, LD
    JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 121 (01) : 67 - 73
  • [5] QUANTITATIVE ESTIMATION OF RHYNCHOSPOROSIDE PRODUCED AND DEGRADED INVITRO AND INVIVO
    RAFENOMANANJARA, D
    FRABOULET, N
    AURIOL, P
    PLANT SCIENCE LETTERS, 1979, 14 (04): : 337 - 344
  • [6] DECEREBRATE RIGIDITY PRODUCED IN CATS BY FOCAL STEREOTACTIC RADIOFREQUENCY LESIONS
    TSEMENTZIS, SA
    GILLINGHAM, FJ
    GORDON, A
    HITCHCOCK, ER
    CAMPBELL, D
    MENDELOW, AD
    ACTA NEUROCHIRURGICA, 1981, 59 (1-2) : 13 - 33
  • [7] Characterization of lesions produced by pulmonary vein isolation with radiofrequency balloon
    Gomez, Eduardo Martinez
    Aranda, Ricardo Salgado
    Cuervo, David Calvo
    Vallejo, Carmen Sanchez
    Filgueiras-Rama, David
    Perez-Castellano, Nicasio
    REVISTA ESPANOLA DE CARDIOLOGIA, 2024, 77 (03): : 267 - 269
  • [8] Lesions produced by radiofrequency ablation of the cavotricuspid isthmus in an experimental model
    Cabeza, P
    Madrid, AH
    Palmero, A
    Rebollo, JM
    Peña, G
    Escobar, C
    Bueno, MG
    Correa, C
    Chércoles, A
    Marín, I
    Bernal, E
    Peng, J
    Nannini, S
    Limón, L
    Viana, M
    Moro, C
    REVISTA ESPANOLA DE CARDIOLOGIA, 2003, 56 (10): : 963 - 970
  • [9] HYPERTHERMIA IN AN INVITRO-INVIVO SYSTEM
    BAKER, ML
    NAGLE, WA
    MOSS, AJ
    RADIATION RESEARCH, 1980, 83 (02) : 463 - 463
  • [10] Changes in the spectral characteristics of ventricular fibrillation in lesions produced by radiofrequency ablation.: An experimental study
    Chorro, Francisco J.
    Guerrero, Juan
    Canoves, Joaquin
    Trapero, Isabel
    Mainar, Luis
    Pelechano, Francisca
    Blasco, Estrella
    Such-Miquel, Luis
    Ferrero, Angel
    Sanchis, Juan
    Bodi, Vicente
    Cerda, Jose M.
    Alberola, Antonio
    Such, Luis
    REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (04): : 394 - 403